X-ray Image Detection by Electronic Methods.

نویسنده

  • G A HAY
چکیده

In diagnostic radiology, the excellence of the conventional radiographic screen-film combination as a means of detecting and displaying the X-ray pattern (the radiation image) is qualified by its inability to show movement. The technique of fluoroscopy, in which the light image on the fluorescent screen is viewed by the dark-adapted but otherwise unaided eye, has long been employed in an attempt to overcome this disadvantage. Unfortunately, because of restricted optical aperture and low retinal efficiency, the eye responds to only a very small fraction of the light emitted by the screen, and only about one-fifth of the information inherent in the screen image is transmitted to the brain. This inefficiency of information transfer also renders it necessary in clinical work to use dose-rates which are higher than appear at present to be desirable. These fundamental deficiencies, together with the inconvenience of the darkened room which can be a great handicap in complex techniques such as cardiac catheterization, seriously limit the clinical applications of fluoroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

Empirical correlation for porosity deduction from X-ray computed tomography (CT)

For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...

متن کامل

Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

Background: Recently, it has been indicated that X-ray coherent scatter from biological tissues can be used to access signature of tissue. Some scientists are interested in studying this effect to get early detection of breast cancer. Since experimental methods for optimization are time consuming and expensive, some scientists suggest using simulation. Monte Carlo (MC) codes are the best...

متن کامل

Morphological and Crystallographic Characterization of Nanoparticles by Granulometry Image Analysis and Rietveld Refinement Methods

The particle size distribution of the resultant cobalt ferrite samples was determined from Scanning Electron Microscopy (SEM) images using the granulometry image analysis method. Results showed the nanosized particles of the samples. The X-Ray Diffraction (XRD) patterns of samples were also analyzed by Rietveld refinement method. The results indicated that the precipitated sample at 95 <sup...

متن کامل

Detection of zinc-lead mineralization and associated alteration in the Mehdiabad deposit, Yazd province, using ASTER and Landsat 8-OLI satellite images

The Mehdiabad zinc-lead deposit, which is located at the East of Mehriz city, is a carbonate-hosted ore deposit lying in the dolomitic rocks of Taft Formation. This deposit is composed of oxide-carbonate and sulfide ores. Different spectral processing techniques were applied to ASTER and Landsat 8-OLI multispectral images to detect different mineralization zones and associated alterations. In O...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 40  شماره 

صفحات  -

تاریخ انتشار 1964