Rehabilitating destructed reinforced concrete T connections by steel straps

نویسنده

  • Muhammad N. S Hadi
چکیده

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection represents a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised steel straps were used to rehabilitate the connection. Epoxy resin was used to fix the steel straps to the concrete surface. The connection was tested after the rehabilitation. Results of testing the rehabilitated connection show that the yield and ultimate loads were 65 kN and 95 kN, respectively, compared with the original test results of 75 kN and 84 kN, respectively. Based on results of the tests, it can be concluded that the rehabilitating method used in this study was effective in increasing the ultimate strength of the T connection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strengthening reinforced concrete T connections by steel straps

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...

متن کامل

Automated Design Guidance for the Repair & Retrofit of Concrete Bridge Structures with Frp

1.1 Background Fibre Reinforced Polymers (FRP’s) have seen active use for strengthening applications in construction since the late 1980’s. They are now securely placed to replace the ageing technologies used in the commonly termed, ‘traditional methods’ of strengthening, which have customarily resulted in an increased cross-section size with the provision of additional reinforced concrete, or ...

متن کامل

Carbon Fiber Post-Strengthening of Concrete Structures

Introduction In the 1970s, exterior bonded steel reinforcement was used sporadically to reinforce bridges to attain higher service load capacities. This steel post-strengthening system consisted of steel straps bonded with epoxies to the exterior of concrete beams. An alternative to the steel retrofit is woven carbon fiber reinforced polymer fabric applied in the same manner as steel. Carbon fi...

متن کامل

Retrofitting of Reinforced Concrete Beams with Steel Fiber Reinforced Composite Jackets

In the present study, a new method for retrofitting reinforced concrete beam is introduced in which steel-concrete composite jackets containing steel fiber is used. For this purpose, 75% of the peripheral surface of reinforced concrete beams was initially reinforced using steel plates and bolts, and steel fiber reinforced concrete was used between the steel plates and the peripheral surfaces of...

متن کامل

Behaviour of FRP strengthened concrete columns under eccentric compression loading

This paper presents results of testing eccentrically loaded columns externally wrapped with two types of materials. Six cylindrical (205 mm diameter and 925 mm height) plain columns were cast and tested. Half of the columns were wrapped with GFRP and the other half with CFRP. All columns were tested by applying an axial load at 50 mm eccentricity. In each group (GFRP or CFRP wrapped) of columns...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017