The Simulation of the Coded Neutron Source Phase Contrast Imaging

نویسندگان

  • Hang Li
  • Yang Wu
  • Heyong Huo
  • Bin Tang
چکیده

Neutron phase contrast imaging is a recently developmental technique which is based not only on the amplitude like in the projection imaging but also on the contribution of phase alteration of the neutron beam. With the additional contrast from the difference of neutron refraction index in the sample which mainly leads to edge enhancement, phase contrast imaging can show more details about the neutron phase materials, especially some low attenuation contrast materials. But this technique required high L/D which made the neutron flux low at the imaging area and leaded to the long exposure time. Coded neutron source is a novel method which can get both high L/D and neutron flux at the imaging area. Some numerical simulations are done to confirm the flexibility of coded source in neutron phase contrast imaging and some reconstruction algorithms are also be studied. The results shows that the coded source technique can be used in neutron phase contrast imaging and shorten the exposure time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

بررسی امکان استفاده از چشمه های نوترونی رادیوایزوتوپی در نوترون درمانی با بور

  Background : Performing successful BNCT experiments needs a suitable neutron source. Important factors of the neutron beam are flux and energy that are very important in the selection of neutron source. In most centers that use this method for treatment, reactor is a neutron source, which according to characteristics of the reactor appropriated neutrons are very high. High cost of constructin...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

Feasibility of single-view coded source neutron transmission tomography

In a simulation experiment, we study the feasibility of single-view coded source neutron transmission tomography for imaging water density in fuel cells at the NIST neutron imaging facility. In standard two-dimensional transmission tomography, one reconstructs a spatially varying attenuation image based on many projections or views of an object. Here, we consider the limiting case where only on...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016