Myocardial area at risk and salvage measured by T2-weighted cardiovascular magnetic resonance: Reproducibility and comparison of two T2-weighted protocols
نویسندگان
چکیده
BACKGROUND Late gadolinium enhancement (LGE) and T2-weighted cardiovascular magnetic resonance (CMR) provides a means to measure myocardial area at risk (AAR) and salvage. Several T2-weighted CMR sequences are in use, but there is no consensus in terms of which sequence to be the preferred. Therefore, the aim of the present study was to: (1) Assess the reproducibility and (2) compare the two most frequently used T2-weighted CMR protocols for measuring AAR and salvage. METHODS 91 patients with ST-elevation myocardial infarction treated with primary percutaneous coronary intervention underwent a CMR scan 1-7 days after initial treatment. Two different T2-weighted protocols, varying in slice thickness and echo time (TE), were applied covering the entire left ventricle (LV) (protocol 1: TE 65 msec and slice thickness 15 mm; protocol 2: TE 100 msec and slice thickness of 8 mm). On a second scan performed 3 months later, infarct size was assessed with a standard LGE sequence. The two protocols were compared in terms of AAR and salvage index. Furthermore, intra- and interobserver reproducibility were assessed. RESULTS Protocol 1 measures a larger AAR and salvage index than protocol 2 with a mean difference in AAR of 1±8%LV (p<0.01) and 6±12 g (p<0.01) and salvage index of 0.04±0.12 (p<0.01). Both protocols had a high intra- and interobserver reproducibility with acceptable limits of agreement (6-8%LV and 6-12 g in AAR and 0.06-0.08 in salvage index). CONCLUSIONS We report acceptable reproducibility for AAR and salvage index measured by T2-weighted images. Thus CMR is a reliable tool for measuring AAR and salvage index. Protocol 2 (8 mm slice thickness and 100 msec TE) measures slightly smaller AAR than protocol 1 (15 mm slice thickness and 65 msec TE), but the present study does not allow for a clear recommendation of either of the protocols.
منابع مشابه
Cardiovascular magnetic resonance of the myocardium at risk in acute reperfused myocardial infarction: comparison of T2-weighted imaging versus the circumferential endocardial extent of late gadolinium enhancement with transmural projection
BACKGROUND In the situation of acute coronary occlusion, the myocardium supplied by the occluded vessel is subject to ischemia and is referred to as the myocardium at risk (MaR). Single photon emission computed tomography has previously been used for quantitative assessment of the MaR. It is, however, associated with considerable logistic challenges for employment in clinical routine. Recently,...
متن کاملT2-weighted cardiovascular magnetic resonance in acute cardiac disease
Cardiovascular magnetic resonance (CMR) using T2-weighted sequences can visualize myocardial edema. When compared to previous protocols, newer pulse sequences with substantially improved image quality have increased its clinical utility. The assessment of myocardial edema provides useful incremental diagnostic and prognostic information in a variety of clinical settings associated with acute my...
متن کاملBright-blood T2-weighted MRI has higher diagnostic accuracy than dark-blood short tau inversion recovery MRI for detection of acute myocardial infarction and for assessment of the ischemic area at risk and myocardial salvage.
BACKGROUND T2-Weighted MRI reveals myocardial edema and enables estimation of the ischemic area at risk and myocardial salvage in patients with acute myocardial infarction (MI). We compared the diagnostic accuracy of a new bright-blood T2-weighted with a standard black blood T2-weighted MRI in patients with acute MI. METHODS AND RESULTS A breath-hold, bright-blood T2-weighted, Acquisition for...
متن کاملMyocardium at risk in ST-elevation myocardial infarction: comparison of T2-weighted edema imaging with the endocardial surface area assessed by magnetic resonance and validation against angiographic scoring
Results The AAR assessed by T2-weighted imaging showed a good correlation with the angiographic AAR (r=0.87; p<0.001), whereas the ESA showed only a moderate correlation either to T2-weighted imaging (r=0.56; p<0.001) and the APPROACH-Score (r=0.44; p<0.001). Mean AAR by ESA (20.0±11.7%LV) was significantly smaller than AAR by T2-weighted imaging and APPROACHScore (p<0.001 respectively) and sho...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 13 شماره
صفحات -
تاریخ انتشار 2011