Extracorporeal circuit sterility after 168 hours.

نویسندگان

  • W V Young
  • C H Heemsoth
  • G Georgiafandis
  • D C Mitchell
  • D K Hackett
  • D G Bahna
چکیده

One of the most important tasks of the perfusionist is the proper assembly of the extracorporeal circuit (ECC) prior to the initiation of cardiopulmonary bypass (CPB). The ECC is usually assembled, primed and debubbled 30 minutes to one hour prior to the patient entering the operating room. But there are occasions when the ECC may have been set up and the previously scheduled procedure cancelled. Perfusionists in this situation have found themselves in a quandary; dispose of the ECC because of required nursing compliance and the sterility question, or keep it and use it later because of the economic impact on the "bottom line". Some hospitals may have satisfactorily answered the question of ECC sterility after 24 hours without observation, but the few reported papers regarding this issue, and our desire to save these circuits, inspired us to find out if they were in fact sterile after having been open for a long period of time. The purpose of this study was to evaluate ECC sterility using an open reservoir oxygenator, over a time period of seven days. After obtaining 792 bacterial cultures from three sites within the ECC, the study was terminated. There were no positive bacterial cultures during the study period. Assuming there is no deliberate contamination, pump circuits assembled in an unused operating room can be maintained sterile for a period of seven days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterility of Previously Assembled Cardiopulmonary Bypass Circuits

The sterility of previously assembled cardiopulmonary bypass circuits was investigated for 17 extracorporeal circuits. The closed circuits were assembled using aseptic technique and remained in the operating room until the time of use. The mean time from point of setup to point of priming for the 17 randomly chosen circuits was 21.47 hours, with a range of 13.50 to 60.50 hours. Circuits were pr...

متن کامل

Use of the CDI blood parameter monitoring system 500 for continuous blood gas measurement during extracorporeal membrane oxygenation simulation.

UNLABELLED The Oximetrix III Opticath (Abbott Critical Care Systems) is used for continuous measurement of venous saturation in a variety of applications, including extracorporeal membrane oxygenation (ECMO), despite clinical reports that have presented data showing poor accuracy of these devices. The CDI Blood Parameter Monitoring System 500 (Terumo) is an inline blood gas monitoring tool comm...

متن کامل

Propofol, midazolam, vancomycin and cyclosporine therapeutic drug monitoring in extracorporeal membrane oxygenation circuits primed with whole human blood

INTRODUCTION As a result of drug sequestration and increased volume of distribution, the extracorporeal membrane oxygenation (ECMO) procedure might lead to a decrease in drug concentrations during a patient's treatment. The aim of this study was to evaluate sedative, antibiotic and immunosuppressive drug loss in ECMO circuit using ex-vivo and in-vitro experiments. METHODS Blood concentrations...

متن کامل

Association of Extracorporeal Membrane Oxygenation Support Adequacy and Residual Lesions With Outcomes in Neonates Supported After Cardiac Surgery.

OBJECTIVES There is a paucity of data regarding the impact of extracorporeal membrane oxygenation support, adequacy of surgical repair, and timing of intervention for residual structural lesions in neonates cannulated to extracorporeal membrane oxygenation after cardiac surgery. Our goal was to determine how these factors were associated with survival. DESIGN Retrospective study. SETTING Ca...

متن کامل

A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model.

In the United States, standardization of neonatal extracorporeal membrane oxygenation (ECMO) circuit was achieved during the 1980s. Since that time, the consoles and components of the ECMO circuit have remained fundamentally unchanged (bladder, rollerpump, silicone membrane oxygenator). Extracorporeal technology, however, has witnessed many significant advancements in components during the past...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 1997