SU-E-T-445: A Dosimetric Comparison of Gamma Knife Plans with Measurement Based and Image Based Skull Definitions.
نویسندگان
چکیده
PURPOSE To compare gamma knife treatment plans that use skull scaling instrument measurements for skull definition vs. CT based skull definition. METHODS Eight previously treated patients who had head CT scans were randomly selected. Their CT images were imported into Leksell GammaPlan. For each patient, three dose plans were developed: 1. the reference plan. It was planned based on the standard clinical treatment planning guidelines. Measurements were used for skull definition and TMR10 for dose calculation algorithm. 2. CT TMR10 plan, a recalculation of the reference plan with CT images used for skull definition 3. CT Convolution plan, a recalculation of the TMR10 plan using convolution algorithm. The treatment times for CT TMR10 plan and CT convolution plan were set to be the same as the reference plan by adjusting the prescription dose level. Prescription dose and shots were left unchanged. Plan comparisons were carried out using minimum dose, target coverage, gradient index and selectivity. RESULTS On average, the minimum dose for CT TMR10 and CT Convolution plans are 1.8% and 6.5% lower than that of the reference plan. The target coverage, gradient index are comparable for these three plans. The selectivity indices for CT TMR10 and CT Convolution plans were found to be 3.1% and 9.8% higher than that of reference plan. CONCLUSIONS This work indicates the measurement based skull definition could Result in inaccurate calculation in minimum dose to the target. The target coverage and gradient index are however uncompromised. The selectivity index was actually underestimated.
منابع مشابه
SU-E-T-402: Coordinate Transformation after Stereotactic Frame Reapplication in Gamma Knife Radiosurgery.
PURPOSE In Gamma Knife (GK) radiosurgery, the occurrence of reapplying the stereotactic frame due to collision with the collimator leads to re- examination and re-planning. For the treatment of vascular lesions, it is a burden not only to physicians but also to patients to get invasive angiography procedure again. To avoid undergoing second angiography examination, and reduce re-planning time, ...
متن کاملGamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data
Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surroun...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملEffect of skull contours on dose calculations in Gamma Knife Perfexion stereotactic radiosurgery
In treatment planning of Leksell Gamma Knife (LGK) radiosurgery, the skull geometry defined by generally dedicated scalar measurement has a crucial effect on dose calculation. The LGK Perfexion (PFX) unit is equipped with a cone-shaped collimator divided into eight sectors, and its configuration is entirely different from previous model C. Beam delivery on the PFX is made by a combination of ei...
متن کاملComparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code
Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part17 شماره
صفحات -
تاریخ انتشار 2012