Dose volume uniformity index: a simple tool for treatment plan evaluation in brachytherapy
نویسنده
چکیده
PURPOSE In radiotherapy treatment planning, dose homogeneity inside the target volume plays a significant role in the final treatment outcome. Especially in brachytherapy where there is a steep dose gradient in the dose distribution inside the target volume, comparing the plans based on the dose homogeneity helps in assessing the high dose volume inside the final treatment plan. In brachytherapy, the dose inhomogeneity inside the target volume depends on many factors such as the type of sources, placement of these radioactive sources, distance between the applicators/implant tubes, dwell time of the source, etc. In this study, a simple index, the dose volume uniformity index (DVUI), has been proposed to study the dose homogeneity inside the target volume. This index gives the total dose volume inhomogeneity inside a given prescription isoline. MATERIAL AND METHODS To demonstrate the proposed DVUI in this study, a single plane implant (breast: 6 catheters), a double plane implant (breast: 9 catheters) and a tongue implant (5 catheters) were selected. The catheters were reconstructed from the CT image datasets in the Plato treatment planning system. The doses for the single, double and tongue implants were prescribed to the reference dose rate as per the Paris technique. DVUI was computed from the cumulative dose volume histogram. RESULTS For a volume receiving a uniform dose inside the prescription isoline, the DVUI is 1. Any value of DVUI > 1 shows the presence of a relatively high dose volume inside the prescription isoline. In addition to the concept of DVUI, a simple conformality index, the dose volume conformality index (DVCI), has also been proposed in this study based on the DVUI. CONCLUSION The DVUI and the proposed DVCI in this study provide an easy way of comparing the rival plans in brachytherapy.
منابع مشابه
Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans
Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...
متن کاملQualitative Dosimetric and Radiobiological Evaluation of High – Dose – Rate Interstitial brachytherapy Implants
Radiation quality indices (QI), tumor control probability (TCP), and normal tissue complication probability(NTCP) were evaluated for ideal single and double plane HDR interstitial implants. In the analysis, geometrically-optimized at volume (GOV) treatment plans were generated for different values of inter-source-spacing (ISS) within the catheter, inter-catheter-spacing (ICS), and inter-plane-s...
متن کاملAssessment of dose homogeneity in conformal interstitial breast brachytherapy with special respect to ICRU recommendations
PURPOSE To present the results of dose homogeneity analysis for breast cancer patients treated with image-based conformal interstitial brachytherapy, and to investigate the usefulness of the ICRU recommendations. MATERIAL AND METHODS Treatment plans of forty-nine patients who underwent partial breast irradiation with interstitial brachytherapy were analyzed. Quantitative parameters were used ...
متن کاملQuality of interstitial PDR-brachytherapy-implants of head-and-neck-cancers: predictive factors for local control and late toxicity?
BACKGROUND AND PURPOSE Parameters and indices related to the implant geometry in use for describing the quality of volume implants in interstitial brachytherapy were developed on the basis of LDR-brachytherapy. The aim of our study was to evaluate their usefulness for predicting late toxicity and local control in the PDR-brachytherapy of head-and-neck-tumors. PATIENTS AND METHODS Between Janu...
متن کاملTreatment planning for multicatheter interstitial brachytherapy of breast cancer – from Paris system to anatomy-based inverse planning
In the last decades, treatment planning for multicatheter interstitial breast brachytherapy has evolved considerably from fluoroscopy-based 2D to anatomy-based 3D planning. To plan the right positions of the catheters, ultrasound or computed tomography (CT) imaging can be used, but the treatment plan is always based on postimplant CT images. With CT imaging, the 3D target volume can be defined ...
متن کامل