Relative quantification of amine-containing metabolites using isobaric N,N-dimethyl leucine (DiLeu) reagents via LC-ESI-MS/MS and CE-ESI-MS/MS.

نویسندگان

  • Ling Hao
  • Xuefei Zhong
  • Tyler Greer
  • Hui Ye
  • Lingjun Li
چکیده

Tandem mass spectrometry (MS/MS)-based relative quantification by isobaric labeling is a useful technique to compare different metabolic expression levels in biological systems. For the first time, we have labeled primary and secondary amine-containing small molecules using 4-plex isobaric N,N-dimethyl leucine (DiLeu) to perform relative quantification. Good labeling efficiency and quantification accuracy were demonstrated with a mixture of 12 metabolite standards including amino acids and small molecule neurotransmitters. Labeling amine-containing metabolites with DiLeu reagents also enabled the separation of polar metabolites by nanoRPLC and improved the detection sensitivity by CE-ESI-MS. The 4-plex DiLeu labeling technique combined with LC-MS/MS and CE-MS/MS platforms were applied to profile and quantify amine-containing metabolites in mouse urine. The variability of concentrations of identified metabolites in urine samples from different mouse individuals was illustrated by the ratios of reporter ion intensities acquired from online data-dependent analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Custom 4-Plex DiLeu Isobaric Labels Enable Relative Quantification of Urinary Proteins in Men with Lower Urinary Tract Symptoms (LUTS)

The relative quantification of proteins using liquid chromatography mass spectrometry (LC-MS) has allowed researchers to compile lists of potential disease markers. These complex quantitative workflows often include isobaric labeling of enzymatically-produced peptides to analyze their relative abundances across multiple samples in a single LC-MS run. Recent efforts by our lab have provided scie...

متن کامل

High temperature liquid chromatography hyphenated with ESI-MS and ICP-MS detection for the structural characterization and quantification of halogen containing drug metabolites.

In this paper we describe the hyphenation of high temperature liquid chromatography with ICP-MS and ESI-MS for the characterization of halogen containing drug metabolites. The use of temperature gradients up to 200°C enabled the separation of metabolites with low organic modifier content. This specific property allowed the use of detection methods that suffer from (significant) changes in analy...

متن کامل

Probing the mechanism of the Ugi four-component reaction with charge-tagged reagents by ESI-MS(/MS).

The mechanism of the Ugi four-component reaction has been investigated by electrospray ionization (tandem) mass spectrometry using charge-tagged reagents (a carboxylic acid or an amine) to favour detection. Key intermediates were transferred directly via ESI(+) from the reaction solution to the gas phase and characterized by MS measurements and MS/MS collision induced dissociation. The Mumm rea...

متن کامل

Isotope-labeled differential profiling of metabolites using N-benzoyloxysuccinimide derivatization coupled to liquid chromatography/high-resolution tandem mass spectrometry.

RATIONALE An isotopic labeling strategy based on derivatizing amine-containing metabolites has been developed using light ((12) C6 ) and heavy ((13) C6 ) N-benzoyloxysuccinimide reagents for semi-targeted metabolomic applications. METHODS Differentially labeled samples were combined and analyzed simultaneously by liquid chromatography/high-resolution tandem mass spectrometry (LC/HR-MS/MS) to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 140 2  شماره 

صفحات  -

تاریخ انتشار 2015