Current Harmonic Compensation and Power Factor Improvement by Hybrid Shunt Active Power Filter
نویسندگان
چکیده
In this paper the current harmonic can be compensated by using the Shunt Active Power Filter, Passive Power Filter and the combination of both. The system has the function of voltage stability, and harmonic suppression. The reference current can be calculated by dq transformation. An improved generalized integrator control was proposed to improve the performance of APF. The simulation results of the nonlinear systems have been carried out with MATLAB 7.6.
منابع مشابه
Pi, Fuzzy Logic Controlled Shunt Active Power Filter for Three-phase Four-wire Systems with Balanced, Unbalanced and Variable Loads
This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...
متن کاملDesign and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter
This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...
متن کاملA Novel Approach for Enhancement of Power Quality by Reduction of Total Harmonic Disortion in Three Phase Four Wire System
This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...
متن کاملPower quality enhancement using cascaded multilevel inverter based shunt hybrid active power filter
This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کامل