Continuous control of endotracheal cuff pressure and tracheal wall damage: a randomized controlled animal study

نویسندگان

  • Saad Nseir
  • Alexandre Duguet
  • Marie-Christine Copin
  • Julien De Jonckheere
  • Mao Zhang
  • Thomas Similowski
  • Charles-Hugo Marquette
چکیده

BACKGROUND Intubation is frequently performed in intensive care unit patients. Overinflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. Despite manual control of the cuff pressure, overinflation of the endotracheal cuff is common in intensive care unit patients. We hypothesized that efficient continuous control of the endotracheal cuff pressure using a pneumatic device would reduce tracheal ischemic lesions in piglets ventilated for 48 hours through a high-volume, low-pressure endotracheal tube. MATERIALS AND METHODS Twelve piglets were intubated and mechanically ventilated for 48 hours. Animals were randomized to manual control of the endotracheal cuff pressure (n = 6) or to continuous control of the endotracheal cuff pressure using a pneumatic device (n = 6). In the two groups, we inflated the endotracheal cuff with 50 ml air for 30 minutes, eight times daily. This hyperinflation of the endotracheal cuff aimed at mimicking high-pressure periods observed in intubated critically ill patients. In all animals, the cuff pressure and the airway pressure were continuously recorded for 48 hours. After sacrifice of the study animals, the trachea was removed and opened longitudinally for gross and histological examination. A pathologist evaluated the slides without knowledge of treatment group assignment. RESULTS The cuff pressure was significantly lower in piglets with the pneumatic device than in piglets without the pneumatic device (median (interquartile range), 18.6 (11-19.4) cmH2O versus 26 (20-56) cmH2O, P = 0.009). No significant difference was found in the percentage of time spent with a cuff pressure <15 cmH2O and that with a cuff pressure between 30 and 50 cmH2O. The percentage of time between 15 and 30 cmH2O of cuff pressure, however, was significantly higher in piglets with the pneumatic device than in piglets without the pneumatic device (98% (95-99%) versus 65% (44-80%), P = 0.002). In addition, the percentage of time with cuff pressure >50 cmH2O was significantly lower in piglets with the pneumatic device than in piglets without the pneumatic device (0% versus 19% (12-41%), P = 0.002). In all animals, hyperemia and hemorrhages were observed at the cuff contact area. Histological examination showed no difference in tracheal lesions between animals with and without the pneumatic device. These lesions included deep mucous ulceration, squamous metaplasia and intense mucosal inflammation. No cartilage lesions were observed. CONCLUSION The pneumatic device provided effective continuous control of high-volume, low-pressure endotracheal cuff pressure in piglets mechanically ventilated for 48 hours. In the present model, however, no significant difference was found in tracheal mucosal lesions of animals with or without a pneumatic device. Further studies are needed to determine the impact of continuous control of cuff pressure over a longer duration of mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated cuff pressure modulation: a novel device to reduce endotracheal tube injury.

OBJECTIVE To assess whether dynamically modulating endotracheal tube (ETT) cuff pressure, by decreasing it during each ventilatory cycle instead of maintaining a constant level, would reduce the extent of intubation-related laryngotracheal injury. DESIGN Single-blind, randomized controlled animal study using a previously validated live porcine model of accelerated intubation-related tracheal ...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

A method for comparing endotracheal cuffs. A controlled study of tracheal trauma in dogs.

Damage to the trachea produced in dogs by large and small residual volume cuffs during 6 h of IPPV was compared using a specially designed endotracheal tube. The cuffs under evaluation were adjusted to exert similar average pressures on the tracheal wall, so that many of the variables believed responsible for tracheal injury were controlled. The true compliance of the cuff was measured with the...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

A canine model of tracheal stenosis induced by cuffed endotracheal intubation

Postintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal stenosis remain not fully understood. We aimed to establish an animal model and to investigate risk factors for postintubation tracheal stenosis. Beagles were intubated with 4 sized tubes (internal diameter 6.5 to 8.0 mm) and cuf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2007