In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs
نویسندگان
چکیده
Purpose To analyze the "in vitro" aberrometric pattern of a refractive IOL and two extended depth of focus IOLs. Methods A special optical bench with a Shack-Hartmann wavefront sensor (SH) was designed for the measurement. Three presbyopia correction IOLs were analyzed: Mini WELL (MW), TECNIS Symfony ZXR00 (SYM), and Lentis Mplus X LS-313 MF30 (MP). Three different pupil sizes were used for the comparison: 3, 4, and 4.7 mm. Results MW generated negative primary and positive secondary spherical aberrations (SA) for the apertures of 3 mm (-0.13 and +0.12 μm), 4 mm (-0.12 and +0.08 μm), and 4.7 mm (-0.11 and +0.08 μm), while the SYM only generated negative primary SA for 4 and 4.7 mm apertures (-0.12 μm and -0.20 μm, resp.). The MP induced coma and trefoil for all pupils and showed significant HOAs for apertures of 4 and 4.7 mm. Conclusions In an optical bench, the MW induces negative primary and positive secondary SA for all pupils. The SYM aberrations seem to be pupil dependent; it does not produce negative primary SA for 3 mm but increases for higher pupils. Meanwhile, the HOAs for the MW and SYM were not significant. The MP showed in all cases the highest HOAs.
منابع مشابه
A Comparison of Reading Performance in Patients Implanted with the Tecnis ZMA00 and AT LISA 802 Multifocal Intraocular Lenses
The choices of intraocular lenses (IOLs) available for implantation in cataract patients are multitudinous. Each option features significant benefits for visual performance and the comfort of the patients, but there are also some inherent limitations in each case. The traditional approach of monofocal IOL implantation is effective in providing adequate distance visual acuity, but is limited in ...
متن کاملHalo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.
PURPOSE To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standar...
متن کاملA comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery
PURPOSE Akreos AO and Kontur AB are two commonly used intraocular lenses (IOLs) in Iran. This study was designed to evaluate the visual performance of these lenses. METHODS In a comparative interventional study, 35 patients (70 eyes) were recruited, and each IOL was implanted in one eye of the patients, randomly. Best corrected visual acuity (BCVA), contrast sensitivity, aberrometric analysis...
متن کاملBilateral implantation of asymmetrical diffractive multifocal intraocular lenses.
OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...
متن کاملComparison of two laboratory-based systems for evaluation of halos in intraocular lenses
Purpose Multifocal intraocular lenses (IOLs) can be associated with unwanted visual phenomena, including halos. Predicting potential for halos is desirable when designing new multifocal IOLs. Halo images from 6 IOL models were compared using the Optikos modulation transfer function bench system and a new high dynamic range (HDR) system. Materials and methods One monofocal, 1 extended depth of...