ID: 4805 Title: For small field Radiosurgery Intermediate Energy Photons (800kV) show superior dose distributions compared to megavoltage beams Purpose: Beam penumbra is significant when using stereotactic radiosurgery to treat small volumes with limited microscopic extensions. It is challenging to irradiate these lesions if a highly critical structure is in close contact with the target. Previous Monte Carlo simulation has demonstrated that using Intermediate Energy Photons (IEP, above orthovoltage and below megavoltage) dramatically reduces the radiological penumbra for small field size radiosurgery (2 x 2cm) when compared to a standard 6 MV beam. This study aims at evaluating the dosimetric benefit of IEP. Methods: A virtual IEP unit based on an 800 kV beam spectrum was described in the Pinnacle TPS including an extended kernel library to the kilovoltage range. A head phantom with a 1cm diameter target volume situated in the middle of the brain and at 1mm from a critical structure was used to assess the dosimetric advantage of IEP compared to 6MV beam. An 11 beam non-coplanar arrangement was used to cover the GTV without margin and a dose of 1000cGy was prescribed. Cumulative DVHs were generated for both energies and for the target, the critical structure and the entire brain. Optimal dosing percentages were chosen for dose normalization to ensure comparable target coverage. Results: The 800 kV and 6MV beams were dosed to 92% and 78% isodose lines respectively. DVHs demonstrate that the volume of critical structure that received 40% of the given dose was 5.5 % versus 10 %, and the maximum dose received by the target was 110% and 127% for the 800 kV and 6MV beams respectively. The increase in integral dose to the brain for the 800 kV beam is negligible. Conclusions: An 800 kV beam shows improvements in dose distribution conformality, homogeneity, and critical structure sparing compared to a standard 6MV beam.
منابع مشابه
Calculations of absorbed dose and energy dependent of small-scale dosimeters for photons beam therapy
In this study, the energy dependency for dosimeters of air ionization chambers, lithium fluoride, silicon and plastic scintillator has been studied using the MCNPX Monte Carlo simulation code and simulated for gamma energy in the range of radiotherapy energy. The simulation results show that the response of each of the dosimeters for gamma photon beams in the energy range of 0.2 to 20 MeV varie...
متن کاملComparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams
Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...
متن کاملClinical implementation of electron energy changes of Varian linear accelerators
Modern dual photon energy linear accelerators often come with a few megavoltage electron beams. The megavoltage electron beam has limited range and relative sharp distal falloff in its depth dose curve compared to that of megavoltage photon beam. Its radiation dose is often delivered appositionally to cover the target volume to its distal 90% depth dose (d90), while avoiding the normal--sometim...
متن کاملCalculating Weighting Factors for Mixing Megavoltage Photon Beams to Achieve Desirable Dose Distribution in Radiotherapy
Background: In radiotherapy, low-energy photon beams are better adapted to the treated volume, and the use of high-energy beams can reduce hot spots in the radiation therapy. Therefore, mixing low and high energies with different ratios can control the rate of hotspots, as well as the dose distribution of the target volume.Material and Methods: The percentage depth doses (PDDs) were calculated ...
متن کاملDetermination of the attenuation coefficient for megavoltage photons in the water phantom
Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...