In Situ Measurement of Pecan Leaf Nitrogen Concentration using a Chlorophyll Meter and Vis-near Infrared Multispectral Camera
نویسندگان
چکیده
Knowledge of foliar nitrogen (N) concentration is important in pecan [Carya illinoinensis (Wang.) K. Koch] management protocols. Lower cost and/or rapid methods to determine foliar N are desirable and may result in improved management strategies as well as enable precision agricultural practices to be deployed in pecan production. This study investigates using a portable chlorophyll meter and Vis-NIR camera to rapidly determine pecan foliar N in situ. Relationships of SPAD values from a chlorophyll meter (Minolta SPAD 502Plus) and vegetative indices calculated from camera image data to foliar N determined by chemical analysis were investigated. SPAD readings were taken monthly from May through October on ‘Pawnee’, ‘Kanza’, and ‘Maramec’ pecan cultivars in Oklahoma in 2010. Images of the same ‘Pawnee’ and ‘Kanza’ trees were collected in September and October of 2010 with a truck-mounted multispectral camera using ambient light. Correlation of foliar N to SPAD values was poor in May for all cultivars but distinct significant linear relationships were found for ‘Maramec’ and ‘Pawnee’ for each of the other months tested with R ranging from 0.40 to 0.87. Data from ‘Kanza’ had significant relationships in June and October with R of 0.39 and 0.72, respectively. Normalized difference vegetative index (NDVI) and reflectance data extracted from Vis-NIR camera images were significantly correlated to foliar N in both months of the study on ‘Pawnee’ but only in September for ‘Kanza’. The various relationships had R between 0.21 and 0.51. Nitrogen management in pecan orchards is important for tree health, optimizing yield, and managing alternate bearing (Conner and Worley, 2000; Smith et al., 2007; Wood et al., 2004). Overapplication of N wastes resources and can cause environmental harm. Availability of N depends not only on fertilizer application rate, type, and time of application, but also on a variety of cultural practices and environmental conditions, including soil nutrients and properties, weather and climate, irrigation practices, tree condition, orchard floor management, and nut production (McDonald et al., 1991; Soria-Ruiz et al., 2007; Ye et al., 2008). Soil tests and leaf analysis are used to measure N; however, leaf analysis is widely used commercially in pecan to assess N concentration during the growing season because it provides a direct measurement of nutrient status in the tree. The traditional practice for measuring N levels in a pecan orchard consists of handharvesting specific leaves that are then dried and sent to a laboratory for chemical analysis. This process takes considerable time and is typically used to guide the subsequent year’s fertility program rather than adjusting N in the current year. Generally only a subset of the trees in an orchard is tested to reduce cost. A sensor that provides an immediate indication of pecan foliar N in the field would be desirable if it provides adequate performance at a reasonable cost. Such a sensor would also be a key component to enable precision agriculture practices in pecan production. Much of the N in a leaf is partitioned in chlorophyll; thus, a sensor that measures chlorophyll can often be used to quantify the amount of N in a leaf (Filella et al., 1995). The basis for most optical sensing of N in leaves is based on chlorophyll’s spectral response to light. Chlorophyll absorbs blue and red light (l 450 and 650 nm, respectively) and reflects near infrared (NIR) light (l greater than 750 nm). The intensity of transmitted and/or reflected light at these wavelengths can be used to form empirical relationships, which estimate chlorophyll concentration and, consequently, N concentration in a leaf (Richardson et al., 2002). A SPAD meter (Konica Minolta, Osaka, Japan) is a handheld device that measures light intensity at wavelengths of 650 and 940 nm transmitted through a 2 · 3-mm area of a leaf clamped in the instrument. The SPAD meter calculates a unitless value between 1 and 100 that has been shown to be positively correlated to leaf chlorophyll concentration. Regression analysis can then be used to predict foliar N from SPAD readings (Markwell et al., 1995). Originally developed for rice, SPAD meters have found use on a variety of field and tree crops for predicting N concentrations (Chang and Robison, 2003; Gianquinto et al., 2004; Neilsen et al., 1995; Perry and Davenport, 2007; Simorte et al., 2001; van den Berg and Perkins, 2004; Wood et al., 1992). Reflectance measurements of Vis-NIR light have also been used to estimate chlorophyll and N status of plants. NDVI is the most widely used measurement and is computed from the intensity of reflected red and NIR light using the following equation: NDVI = (INIR – Ired)/(INIR + Ired). Empirical relationships of NDVI to chlorophyll concentration and N status have been developed for many crops (Hansen and Schjoerring, 2003; Jones et al., 2007; Ma et al., 1995; Plant et al., 2000; Reyniers and Vrindts, 2006). NDVI can be calculated from remotely acquired multispectral digital camera image data or from closeproximity sensors. Remote imaging systems generally measure reflected ambient light, whereas some close-proximity sensors collect reflected light that originates from the sensor itself (Jones et al., 2007). In both cases, the intensity of incident light is required to accurately determine relative intensity of the reflected light to control sensor error. At high levels of biomass, NDVI tends to becomes less sensitive to chlorophyll concentration because reflected red light intensity from leaves asymptotically approaches a minimum. In plant systems where chlorophyll levels are high, vegetative indices (VIs) that include green reflectance may have better performance predicting foliar N than NDVI. Gitelson et al. (1996) compared NDVI to green-NDVI (GNDVI) obtained from satellite images of Norway maple (Acer platanoides L.) and horse chestnut (Aesculus hippocastanum L.) trees and found GNDVI resulted in more accurate predictions of chlorophyll content Received for publication 2 Apr. 2012. Accepted for publication 3 May 2012. To whom reprint requests should be addressed; e-mail [email protected]. HORTSCIENCE VOL. 47(7) JULY 2012 955 MISCELLANEOUS
منابع مشابه
World Congress of the International Commission of Agricultural and Biosystems Engineering (CIGR) NITROGEN ESTIMATION OF OILSEED RAPE USING SPAD AND VIS/NIR SPECTROSCOPY
The estimation of nitrogen status, non-destructively, in oilseed rape was performed using spectral reflectance with visible and near infrared reflectance spectroscopy (Vis/NIRS), and SPAD values of the oilseed rape leaves of 30 plots were measured by a SPAD 502 chlorophyll meter, and the research was carried out at experiment field in the Zhejiang University during growing season from 2007 to 2...
متن کاملNitrogen Concentration Estimation in Tomato Leaves by VIS-NIR Non-Destructive Spectroscopy
Nitrogen concentration in plants is normally determined by expensive and time consuming chemical analyses. As an alternative, chlorophyll meter readings and N-NO(3) concentration determination in petiole sap were proposed, but these assays are not always satisfactory. Spectral reflectance values of tomato leaves obtained by visible-near infrared spectrophotometry are reported to be a powerful t...
متن کاملOptimal Leaf Positions for SPAD Meter Measurement in Rice
The Soil Plant Analysis Development (SPAD) chlorophyll meter is one of the most commonly used diagnostic tools to measure crop nitrogen status. However, the measurement method of the meter could significantly affect the accuracy of the final estimation. Thus, this research was undertaken to develop a new methodology to optimize SPAD meter measurements in rice (Oryza sativa L.). A flatbed color ...
متن کاملDesign of A Hyperspectral Nitrogen Sensing System for Citrus
Abstract. Citrus is one of the most important agricultural crop in Florida. Heavy reliance on agricultural chemicals and low fertilizer efficiencies have raised environmental and economic concerns. In this study, a system to sense nitrogen levels in a single citrus leaf was developed. Based on chlorophyll and protein spectral absorption bands, the sensing system’s wavelength ranges were chosen ...
متن کاملNondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy
Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...
متن کامل