Biological variation of the cardiac index in patients with stable chronic heart failure: inert gas rebreathing compared with impedance cardiography†

نویسندگان

  • Tobias Täger
  • Hanna Fröhlich
  • Jennifer Franke
  • Karen Slottje
  • Andrea Horsch
  • Dietmar Zdunek
  • Georg Hess
  • Andreas Dösch
  • Hugo A Katus
  • Frank H Wians
  • Lutz Frankenstein
چکیده

AIMS In chronic heart failure (CHF), changes in cardiac function define the course of the disease. The cardiac index (CI) is the most adequate indicator of cardiac function. Interpretation of serial CI measurements, however, requires knowledge of the biological variation of CI. Because measurements of CI can be confounded by the clinical situation or the method applied, biological variation might be subject to the same confounders. METHODS AND RESULTS We prospectively included 50 CHF patients who met rigid criteria for clinical stability. CI was measured by both inert gas rebreathing (IGR) and impedance cardiography (ICG) in weekly intervals over 3 weeks-each measurement performed at rest (IGRrest/ICGrest) and during low-exercise 10 Watt pedalling (IGR10W/ICG10W). Intra-class correlation coefficients (ICCs), reference change values, and minimal important differences of CI were determined for IGRrest, ICGrest, IGR10W, and ICG10W. Impedance cardiography and IGR showed moderate agreement at rest (20% (6-36)) and good agreement at 10 Watt (-4% (-23-16)). Depending on time interval, measurement modality for CI, and mode, ICC ranged between 0.42 and 0.78, ICC values for IGR were lower than those for ICG. Reference change value ranged between 3 and 15%, and minimal important difference ranged between 0.2 and 0.5 L/min/m2. Values for IGR were lower at rest and higher at 10 Watt than those for ICG. CONCLUSION Non-invasive measurements of CI are stable over time. Measurement modalities for CI, however, are not interchangeable. Biological variation is less pronounced when obtained by ICG. The influence of low-level exercise on stability of CI depends on the measurement modality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.

Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...

متن کامل

Validation of Noninvasive Measurement of Cardiac Output Using Inert Gas Rebreathing in a Cohort of Patients With Heart Failure and Reduced Ejection Fraction.

BACKGROUND Cardiac output (CO) is a key indicator of cardiac function in patients with heart failure. No completely accurate method is available for measuring CO in all patients. The objective of this study was to validate CO measurement using the inert gas rebreathing (IGR) method against other noninvasive and invasive methods of CO quantification in a cohort of patients with heart failure and...

متن کامل

Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...

متن کامل

Monitoring: Arterial and Pulmonary Artery Catheters

55. Treister N, Wagner K, Jansen PR. Reproducibility of impedance cardiography parameters in outpatients with clinically stable coronary artery disease. Am J Hypertens. 2005;18(Pt 2):44S–50S. 56. Barcarse E, Kazanegra R, Chen A, et al. Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department. Cong...

متن کامل

Impedance Cardiography Accurately

Objectives: After validation of impedance cardiography (ICG) in healthy children, this same device was tested in children with cystic fibrosis (CF) to validate its capability of measuring cardiac output (Q) in this population. Design: Comparative study of ICG vs the indirect Fick (C02) method. Setting: Tertiary care children's teaching hospital. Patients: Twenty-one CF children with mean FEVX o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015