Revision Total Hip Arthroplasty with Retained Acetabular Component.
نویسندگان
چکیده
BACKGROUND Aseptic loosening and osteolysis commonly limit the survivorship of total hip prostheses. Retention of a well-fixed acetabular component, rather than full acetabular revision, has multiple advantages, but questions have lingered regarding the clinical success and prosthetic survivorship following this procedure. We examined the impact of acetabular component position, polyethylene type, liner insertion technique, femoral head size, and simultaneous revision of the entire femoral component (as opposed to head and liner exchange) or bone-grafting on mid-term to long-term prosthetic survival following such limited revisions. METHODS One hundred hips in 100 patients with osteolysis, polyethylene wear, or femoral component loosening underwent revision total hip arthroplasty with retention of the acetabular component. Acetabular component inclination and anteversion were measured on prerevision radiographs and were categorized according to predetermined positional safe zones (inclination of 35° to 55° and anteversion of 5° to 25°). Operative reports were reviewed for femoral head size, polyethylene liner type (conventional or highly cross-linked), liner insertion technique (use of the existing locking mechanism or cementation), whether the patient had revision of the entire femoral component, and use of bone graft. Outcomes of interest included the Harris hip score, University of California at Los Angeles (UCLA) activity score, episodes of instability, and need for repeat revision. RESULTS At an average of 6.6 years (range, two to fourteen years) postoperatively, the Harris hip and UCLA activity scores were both significantly improved compared with the preoperative scores (p < 0.0001 and p < 0.01, respectively). Overall, the failure rate was 13%. In addition, 6% of the patients had postoperative instability. Hips in which the acetabular component was outside of the safe zone for inclination had a higher rate of failure (p = 0.048). Use of conventional, rather than highly cross-linked, polyethylene at the time of revision was also associated with an increased rate of repeat revision (p = 0.025). CONCLUSIONS Revision total hip arthroplasty with retention of the acetabular component is associated with good outcomes in hips with an appropriately positioned, well-fixed acetabular component. Acetabular components outside the safe zone for inclination were at a higher risk for failure, as was use of conventional polyethylene. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
منابع مشابه
Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملAcetabular Reconstruction in Total Hip Arthroplasty
The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component select...
متن کاملReconstruction of acetabulum in revision total hip arthroplasty for pelvic discontinuity: report of a difficult case requiring four revision arthroplasty
BACKGROUND Massive bone defects of the acetabulum with pelvic discontinuity are one of the major problems in revision total hip arthroplasty. Several techniques have been described for repair of acetabular defect; however, reconstruction of acetabulum with massive bone defect is still a major problem. We describe a patient who required four revision total hip arthroplasty during a 24-year perio...
متن کاملRe-revision of failed revision Total Hip Arthroplasty acetabular components.
While revision of total hip arthroplasty (THA) is being performed with increasing frequency, outcomes of repeated revisions have been rarely reported in the literature. The purpose of this study was to report mid-term outcomes of re-revision of failed revision THA acetabular components. We performed at least two revisions of the failed acetabular component in 57 patients (57 hips) between Augus...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 96 12 شماره
صفحات -
تاریخ انتشار 2014