Water-perfused esophageal high-resolution manometry: normal values and validation.

نویسندگان

  • Boudewijn F Kessing
  • Pim W Weijenborg
  • André J P M Smout
  • Sem Hillenius
  • Albert J Bredenoord
چکیده

Water-perfused high-resolution manometry (HRM) catheters with 36 unidirectional pressure channels have recently been developed, but normal values are not yet available. Furthermore, the technique has not been validated and compared with solid-state HRM. We therefore aimed to develop normal values for water-perfused HRM and to assess the level of agreement between water-perfused HRM and solid-state HRM. We included 50 healthy volunteers (mean age 35 yr, range 21-64 yr; 15 women, 35 men). Water-perfused HRM and solid-state HRM were performed in a randomized order. Normal values were calculated as 5th and 95th percentile ranges, and agreement between the two systems was assessed with intraclass correlation coefficient (ICC) statistics. The 5th-95th percentile range was 3.0-6.6 cm/s for contractile front velocity (CFV), 141.6-3,674 mmHg·s·cm for distal contractile integral (DCI), 6.2-8.7 s for distal contraction latency (DL), and 1.0-18.8 mmHg for integrated relaxation pressure (IRP 4s). Mean (SD) and ICC for water-perfused HRM and solid-state HRM were 4.4 (1.1) vs. 3.9 (0.9) cm/s, ICC: 0.49 for CFV; 1,189 (1,023) vs. 1,092 (1,019) mmHg·s·cm, ICC: 0.90 for DCI; 7.4 (0.8) vs. 6.9 (0.9) s, ICC: 0.50 for DL; and 8.1 (4.8) vs. 7.9 (5.1), ICC: 0.39 for IRP 4s. The normal values for this water-perfused HRM system are only slightly different from previously published values with solid-state HRM, and moderate to good agreement was observed between the two systems, with only small differences in outcome measures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal values for water-perfused esophageal high-resolution manometry.

BACKGROUND Normal values for water-perfused esophageal high-resolution manometry have still not been established in our environment, despite its generalized use and the recommendation to determine reference values for each Motility Unit based on their equipment. Normal values established with solid-state highresolution manometry are currently being used as reference values for water-perfused hi...

متن کامل

CALL FOR PAPERS Innovative and Emerging Technologies in GI Physiology and Disease Water-perfused esophageal high-resolution manometry: normal values and validation

Kessing BF, Weijenborg PW, Smout AJ, Hillenius S, Bredenoord AJ. Water-perfused esophageal high-resolution manometry; normal values and validation. Am J Physiol Gastrointest Liver Physiol 306: G491–G495, 2014. First published January 30, 2014; doi:10.1152/ajpgi.00447.2013.—Water-perfused high-resolution manometry (HRM) catheters with 36 unidirectional pressure channels have recently been develo...

متن کامل

Standard values for gas-perfusion manometry of the esophagus

The manometry with water-perfused or solid-state catheters is the predominant diagnostic procedure to detect motility disorders of the esophagus. Another method is the manometry using gas-perfused catheters. Although the high-resolution manometry is the method of first choice, the conventional manometry with helium has some advantages: the simple and hygienically unproblematic use and the absen...

متن کامل

Relationship between esophageal clinical symptoms and manometry findings in patients with esophageal motility disorders: a cross-sectional study

Background: Manometry is the gold-standard diagnostic test for motility disorders in the esophagus. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The diagnostic value of particular esophageal clinical symptoms among patients suspected of esophageal m...

متن کامل

مانومتری با قدرت تفکیک بالا در افتراق اختلالات حرکتی مری

Background: High-resolution manometer (HRM) of the esophagus has become the main diagnostic test in the evaluation of esophageal motility disorders. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The first step of the Chicago classification described ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Gastrointestinal and liver physiology

دوره 306 6  شماره 

صفحات  -

تاریخ انتشار 2014