A Comparison between Cytotoxicity Induced by Two Resin Based Sealers (2Seal and AH Plus) in Saos-2 and MG-63 Cell Lines

نویسندگان

  • Maryam Ehsani
  • Ebrahim Zabihi
  • Hamed Gharouee
چکیده

The aim of this study was to evaluate and compare the cytotoxicity induced by two resin-based sealers, 2Seal and AH Plus, in two osteoblast-like cell lines, MG-63 and Saos-2. Using sterile discs of both sealers in complete media, 24- and 72-h extracts were prepared. The extracts were exchanged with Saos-2 or MG-63 cell culture media at 75% confluence, and after 24 h incubation, cell viability tests were performed for each extract and cell line using MTT and trypan blue dye exclusion assays. Corresponding incubated media were used as negative control groups. For both extracts and sealers, cytotoxicity was observed in both cell lines. For Saos-2, there was no statistical difference in toxicity between the sealers for either extract (p > 0.05). For MG-63, the 2Seal 24-h extract and the AH Plus 72-h extract had greater cytotoxicity than the other extracts (p < 0.05(. Both AH Plus and 2Seal demonstrated significant cytotoxicity in these two cell lines. In contrast to 2Seal, the cytotoxicity of AH Plus in the MG-63 cell line increased with extraction time from 24 to 72 h. The AH Plus and 2Seal 24-h extracts showed different levels of cytotoxicity in the MG-63 cell line, while in the Saos-2 cell line there were no detectable differences. This may reflect higher sensitivity of the MG-63 cell line compared to Saos-2 toward cytotoxicity induced by these two sealers, or different kinetics of toxicant release from the sealers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison between cytotoxicity induced by two resin based sealers (2Seal and AH Plus) in Saos-2 and MG-63 cell lines

The aim of this study was to evaluate and compare the cytotoxicity induced by two resin-based sealers, 2Seal and AH Plus, in two osteoblast-like cell lines, MG-63 and Saos-2. Using sterile discs of both sealers in complete media, 24- and 72-h extracts were prepared. The extracts were exchanged with Saos-2 or MG-63 cell culture media at 75% confluence, and after 24 h incubation, cell viability t...

متن کامل

Comparison of Cytotoxicity of AH Plus and DC Canal SE Sealer After Final Setting

Background and Aim: This study aimed to compare the cytotoxicity of AH Plus and DC Canal SE sealer after final setting. Materials and Methods: In this in vitro, experimental study, human gingival fibroblasts (HGFs) were cultured in Dulbecco’s modified Eagle’s medium supplemented with 10% fetal bovine serum, 100 U/mL penicillin, and 100 µg/mL streptomycin, and incubated at 37°C and 5% CO2. ...

متن کامل

Cytotoxicity of Two Resin-Based Sealers and a Fluoride Varnish on Human Gingival Fibroblasts

INTRODUCTION Assessment of cellular cytotoxicity is a regular method for evaluating the biocompatibility of novel materials. In a recent study, 5% fluoride varnish (Duraflur) has shown reasonable sealing ability and coverage of root canal walls when used as a sealer. The aim of the present study was to compare the cytotoxicity of Duraflur varnish with two popular commonly used root canal sealer...

متن کامل

In Vitro Comparison of Cytotoxicity of Four Root Canal Sealers on Human Gingival Fibroblasts

UNLABELLED The goal of this in vitro study was to evaluate the relative biocompatibility of four endodontic sealers on the cell culture of the human fibroblast through cytotoxicity. MATERIALS AND METHODS In this study four endodontics sealers was used GuttaFlow (Roeko)silicone based sealer, AH plus (De Tray-DENTSPLY) epoxy resin based, Apexit (Vivadent) calcium hydroxide based and Endorez (Ul...

متن کامل

Evaluation of Biocompatibility of Root Canal Sealers on L929 Fibroblasts with Multiscan EX Spectrophotometer

INTRODUCTION The purpose of the current study was to estimate the biocompatibility of endodontic sealers with different bases on L929 mouse fibroblasts permanent cell line using Multiscan EX Spectrophotometer. MATERIALS AND METHODS Endodontics sealers used in this study were GuttaFlow (Roeko) silicone based sealer, AH plus (De Tray-DENTSPLY) epoxy resin based, Apexit (Vivadent) calcium hydrox...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2012