The learning effect in visual field testing of healthy subjects using frequency doubling technology.

نویسندگان

  • Amjad Horani
  • Shahar Frenkel
  • Claudia Yahalom
  • Marilyn D Farber
  • Uriel Ticho
  • Eytan Z Blumenthal
چکیده

PURPOSE To evaluate the presence, duration and magnitude of a learning effect in serial visual field (VF) testing, using the commercially available frequency doubling technology (FDT) instrument. PATIENTS AND METHODS 21 healthy adults with no prior VF experience underwent 6 serial VF tests, using the full-threshold C-20 program of the Zeiss-Humphrey FDT analyzer, on one randomly chosen eye. Tests were spaced at least two days apart. RESULTS The average mean sensitivity was 32.37 +/- 2.6 dB; the average mean deviation (MD) was 1.22 +/- 1.8 dB. The MD at the first examination (0.28 +/- 2.1 dB) was significantly poorer than at any of the other testing sessions (p<0.003). Similarly, the mean sensitivity at the first examination (31.16 +/- 3.0 dB) was significantly lower than any other testing session (p<0.004). The proportion of improvement from the first to the second session was 63% and 65% of the total improvement, for mean sensitivity and MD, respectively. Mean test duration showed a modest reduction, from 4.40 +/- 0.3 minutes in the first session to 4.17 +/- 0.4 minutes in the last session (p = 0.023). A sub-analysis comparison of the different VF segments showed a more prominent learning effect in the peripheral and nasal visual segments (p<0.0001). CONCLUSION Baseline measurements should best rely on the second testing session, since MD and mean sensitivity are somewhat poorer when subjects with no prior VF experience are first tested on the FDT instrument. This may be especially true for the purpose of following patients over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-retest variability in visual field testing using frequency doubling technology.

PURPOSE To quantify the magnitude of test-retest variability (TRV) for normal subjects in serial visual fields (VF) using the frequency doubling technology (FDT) instrument. METHODS Twenty-one healthy adults, aged 23 to 60 years, underwent four serial FDT VF tests, using the full-threshold C-20 program of the Zeiss-Humphrey FDT analyzer, on one randomly chosen eye. The VF tests were spaced 2 ...

متن کامل

Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children

AIMS The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. MATERIALS AND METHODS This prospective study included 55 healthy children without ocular or systemic disorders who underwent both S...

متن کامل

Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects

BACKGROUND To evaluate the relationship and agreement between standard automated perimetry (SAP) and Matrix frequency doubling technology (Matrix-FDT) in subjects with ocular hypertension and healthy control subjects. METHODS Forty-four eyes of 44 ocular hypertensive subjects and 29 eyes of 29 healthy age-matched control subjects were included in this prospective study. All participants under...

متن کامل

The reliability of frequency-doubling perimetry in young children.

OBJECTIVE To evaluate whether healthy young children are able to perform automated static perimetry reliably using the frequency-doubling technology (FDT) perimeter. DESIGN Prospective, observational case series. PARTICIPANTS Forty healthy children aged 4 to 14 years. TESTING Subjects underwent, in 1 randomly chosen eye, 2 consecutive visual field (VF) tests using the C-20 full-threshold ...

متن کامل

Performance of efficient test procedures for frequency-doubling technology perimetry in normal and glaucomatous eyes.

PURPOSE To validate the clinical performance of two new efficient threshold-estimation procedures for frequency-doubling technology (FDT) perimetry in both visually normal individuals and patients with glaucomatous visual field loss. METHODS Forty-one normal subjects (mean age, 48.3 +/- 11.6 years) and 50 patients with glaucomatous visual field loss (mean age, 72.7 +/- 10.0 years) were tested...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 11 6  شماره 

صفحات  -

تاریخ انتشار 2002