Prediction of the effect of mobile-phase salt type on protein retention and selectivity in anion exchange systems.

نویسندگان

  • Nihal Tugcu
  • Minghu Song
  • Curt M Breneman
  • N Sukumar
  • Kristin P Bennett
  • Steven M Cramer
چکیده

This study examines the effect of different salt types on protein retention and selectivity in anion exchange systems. Particularly, linear retention data for various proteins were obtained on two structurally different anion exchange stationary-phase materials in the presence of three salts with different counterions. The data indicated that the effects are, for the most part, nonspecific, although various specific effects could also be observed. Quantitative structure retention relationship (QSRR) models based on support vector machine feature selection and regression models were developed using the experimental chromatographic data in conjunction with various molecular descriptors computed from protein crystal structure geometries. Star plots for each descriptor used in the final model were generated to aid in interpretation. The resulting QSRR models were predictive, with cross-validated r2 values of 0.9445, 0.9676, and 0.8897 for Source 15Q and 0.9561, 0.9876, and 0.9760 for Q Sepharose resins in the presence of three different salts. The predictive power of these models was validated using a set of test proteins that were not used in the generation of these models. Interpretation of the models revealed that particular trends for proteins and salts could be captured using QSRR techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of selectivity in multimodal anion exchange systems: a priori prediction of protein retention and examination of mobile phase modifier effects.

Although recent advances in multimodal chromatography have shown significant potential for selective protein purification, there is a need to establish a deeper understanding of the nature of selectivity in these systems. In this work, the adsorption behavior of a library of commercially available proteins with varying physicochemical properties was investigated. Linear gradient experiments wer...

متن کامل

Identification of chemically selective displacers using parallel batch screening experiments and quantitative structure efficacy relationship models.

Parallel batch screening experiments were carried out to examine how displacer chemistry and salt counterions affect the selectivity of batch protein displacements in anion exchange chromatographic systems. The results indicate that both salt type and displacer chemistry can have a significant impact on the amount of protein displaced. Importantly, the results indicate that, by changing the dis...

متن کامل

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

Anion Control Selectivity of Neutral N4-Type Schiff Base Extractants Towards Transition Metal Ions

Two N4-type Schiff base ligands named N,N'-bis(2-pyridylmethylidene)-1,2-diiminoethane (L1) and N,N'-bis(2-pyridylmethylidene)-1,3-diiminopropane (L2) have been synthesized by the reaction of pyridine-2-carbaldehyde with ethylenediamine and propylenediamine, respectively. The binding abilities of L1 and L2 in dichloromethane towards Cu<...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 14  شماره 

صفحات  -

تاریخ انتشار 2003