Impella: a miniaturized cardiac support system in an era of minimal invasive cardiac surgery.
نویسندگان
چکیده
In modern coronary bypass surgery, new objectives have been set based upon a minimal invasive approach: beating heart surgery is the new trend to follow, although this might not be feasible in more complex cases. In these cases, the beating heart could be supported by a mechanical device, preferably a device with minimal invasive features to fit in this new approach. For this purpose, two intravascular blood pumps were developed: the Intracardiac Pump LV for left ventricular support and the Intracardiac pump RV for right ventricular support. (Impella Cardiotechnik, Aachen, Germany) The Impella pumps are rotary blood pumps of the axial flow type and produce 4.2 L/min at physiological pressure differences and a rotational speed of 32,500 rotations/min. These micropumps can widen the indications of beating heart surgery by sustaining hemodynamic stability and protecting the heart from warm ischemia. The current concept is aimed at bridging a procedure. Therefore, the proof of safe duration of usage has not been extended beyond 6 hours. As the pump-flow is based on standard pressure-flow curves for each so-called "performance level" (resulting from in-vitro experiments), an investigation was conducted to compare this relationship in the in-vitro trials with the findings in pump-supported patients undergoing coronary bypass surgery. It could be concluded that the intracardiac pump is efficacious in assisting coronary bypass surgery.
منابع مشابه
A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience.
OBJECTIVES We sought to evaluate the safety and feasibility of the Impella 2.5 system (Abiomed Inc., Danvers, Massachusetts) in patients undergoing high-risk percutaneous coronary intervention (PCI). BACKGROUND The Impella 2.5 is a miniaturized percutaneous cardiac assist device, which provides up to 2.5 l/min forward flow from the left ventricle into the systemic circulation. METHODS In a ...
متن کاملIn vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.
The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was...
متن کاملRemoval of an Umbilical Catheter Migrated into the Neck in a Neonate: Report of Case
Umbilical and supraumbilical catheter insertion is a common procedure performed in the NICU. It is a safe and usually easy procedure devoid of serious mishaps, morbidity and mortality. Complications such as hemorrhage, infection, hernia, evisceration, omphalitis, portal vein thrombosis and portal hypertension may occur after umbilical catheter insertion. Other uncommon and rare complications re...
متن کامل[Preliminary experience in an intensive care unit with Impella Recover. A new circulatory support system in patients with low cardiac output].
The low cardiac output syndrome following cardiopulmonary bypass is characterized by poor left ventricular contractibility that requires the support of high doses of vasoactive drugs, intra-aortic balloon pump, and sometimes makes it impossible to disconnect the extracorporeal circulation. We report 5 cases in which a "recently created" device in left ventricular support was inserted, the Impel...
متن کاملComparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 34 2 شماره
صفحات -
تاریخ انتشار 2002