Effect of composition, viscosity and thickness of the opaquer on the adhesion of resin composite to titanium.
نویسندگان
چکیده
OBJECTIVES The objectives of this study were to determine the bond strength of powder-liquid and paste opaquers with different chemical compositions and viscosity to a metal substructure when they were applied in two thicknesses and to evaluate the failure modes after the bond strength test. METHODS Titanium plates (51 mm x 25 mm x 1mm) (n(plates)=25, N=80, n=10 per group) were conditioned with chairside silica coating (CoJet-Sand, 30 microm silica coated Al(2)O(3)) from a distance of approximately 10mm at a pressure of 2.8 bar for 15 s/cm(2) and silanized. Four types of opaquers, namely one powder-liquid (Sinfony, 3M ESPE), and three paste opaquers [(Cimara, Voco), (Monopaque, Ivoclar Vivadent), (Cavex Experimental, Cavex)] were applied either in 0.25 or 0.50 mm thicknesses using standard polyethylene molds and photo-polymerized. Resin composite (Quadrant Posterior Dense, Cavex) was applied incrementally and photo-polymerized. The specimens were thermocycled (5-55 degrees C, 6000 cycles) prior to shear bond strength test (1mm/min). Failure types were analyzed using an optical microscope and scores were given according to the modified Adhesive Remnant Index (ARI) (Score 0=no opaquer on the surface, Score 1=<1/2 covered with opaquer, Score 2=>1/2 covered with opaquer, Score 3=completely covered with opaquer). RESULTS While thickness did not significantly affect the bond strength results (p=0.523), type of opaquers had a significant influence on the results (p<0.01) (Univariate ANOVA, Tukey's test). Interaction terms between thickness and opaquer type were significant (p<0.01). Debonded specimens during thermocycling were considered as 0 MPa. At both 0.25 and 0.5mm thicknesses, powder-liquid based opaquer (Sinfony) showed significantly higher results (8.4+/-5.6 and 8.4+/-4.9 MPa, respectively) than those of other opaquers (1.4+/-1 to 4.3+/-3.8 MPa) (p<0.05). Only when Cimara was applied in 0.25 mm (6.9+/-4.2 MPa), there were no significant differences with Sinfony (p>0.05). The lowest results in both thicknesses were obtained from Monopaque (4+/-3.8 to 1.6+/-1 MPa, respectively) and Cavex (1.4+/-1 to 4.2+/-2.9 MPa, respectively) paste opaquers. In all opaquers, the incidence of Score 0 (30) was more frequent followed by Score 1 (27) and Score 2 (20). SIGNIFICANCE The use of powder-liquid opaquer in order to mask the metal in repair actions provided higher bond strength than those of the paste opaquers in both thin and thick applications. In all opaquers, the incidence of adhesive failure between the opaquer and the metal was more common implying inadequate adhesion.
منابع مشابه
Micro-Shear Bond Strength of Indirect Composite Resin to Three Different Computer-Milled Cores After Thermocycling
Background and Aim: The aim of this study was to evaluate the micro-shear bond strength of an indirect composite resin to three different types of cores. Materials and Methods: In this in-vitro study, 14 blocks (5×5×2 mm) were designed and milled by computer from cobalt-chromium (Co-Cr) alloy, zirconia, and polyether ether ketone (PEEK). Each sample was treated according to the manufacturer’s ...
متن کاملIn Vitro Comparison of the Effect of Nano-Hybrid Composite Resin and Amalgam on the Adhesion of Streptococcus Mutans
Background and Aim: Due to the increasing use of restorative materials, finding a suitable material with low adhesion rate and colonization of pathogenic Streptococcus mutans has a significant importance. The purpose of this study was the comparison of the adhesion rate of Streptococcus mutans to “Nano-hybrid composite” and “Amalgam” at 1, 3, and 7 day intervals. Method...
متن کاملSurface Characterization and Tribological Behaviour of Ti-Ni-P Intermetallic Coatings on Titanium Alloys
In this research, tribological behavior of Ti-Ni-P intermetallic coatings on titanium substrates have been investigated under dry reciprocating conditions. Hardness profile testing results exhibit that high surface hardness has been attained and static indentation result shows that the intermetallic coating has better adhesion strength than the conventional ceramic coatings. In this respect, th...
متن کاملSurface Characterization and Tribological Behaviour of Ti-Ni-P Intermetallic Coatings on Titanium Alloys
In this research, tribological behavior of Ti-Ni-P intermetallic coatings on titanium substrates have been investigated under dry reciprocating conditions. Hardness profile testing results exhibit that high surface hardness has been attained and static indentation result shows that the intermetallic coating has better adhesion strength than the conventional ceramic coatings. In this respect, th...
متن کاملEffect of Accelerated Aging on the Color Stability of Light-cured Res-in Cement and Flowable Composite Through Porcelain Laminate Veneer
Background and Aim: Changing the color of resin luting cements could affect the aesthetic appearance of thin porcelain veneer. The aim of this in vitro study was to evaluate the effect of artificially accelerated aging on color stability of light-cured resin cement and flowable composite as a luting agent through the porcelain veneer. Materials and Methods: This experimental study was carried ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Dental materials : official publication of the Academy of Dental Materials
دوره 25 10 شماره
صفحات -
تاریخ انتشار 2009