Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. I. Method setup.
نویسندگان
چکیده
In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.
منابع مشابه
Candidate reference methods for determining target values for cholesterol, creatinine, uric acid, and glucose in external quality assessment and internal accuracy control. II. Method transfer.
We describe the testing of transferability of candidate Reference Methods developed by INSTAND for cholesterol, creatinine, uric acid, and glucose. The methods are based on isotope dilution-gas chromatography--mass spectrometry. The study consisted of two parts: setup of the methods and self-evaluation for readiness in the collaborating laboratory, followed by independent measurements in parall...
متن کاملQuantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics
Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...
متن کاملBehavior of frozen serum pools and lyophilized sera in an external quality-assessment scheme.
To further improve analytical accuracy in clinical chemistry, proficiency testing needs amelioration in the quality of materials tested and in target value assignment. To obtain information on the actual state-of-the-art in the Lombardy region of Italy, and to examine the behavior of different types of control materials (fresh-frozen human sera and lyophilized materials), we developed the follo...
متن کاملDetermination of reference ranges using medical laboratory date
In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from...
متن کاملSigma metrics in clinical chemistry laboratory – A guide to quality control
Background: Six sigma is a process of quality measurement and improvement program used in industries. Sigma methodology can be applied wherever an outcome of a process is to be measured. A poor outcome is counted as an error or defect. This is quantified as defects per million (DPM). Six sigma provides a more quantitative frame work for evaluating process performance with evidence for process i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 39 6 شماره
صفحات -
تاریخ انتشار 1993