Background. It has been suggested that left ventricular unloading at the time of reperfusion provides superior infarct salvage over reperfusion alone. The purpose of this study was to show that the Hemopump transvalvular axial-flow left ventricular assist device provides superior left ventricular unloading, ischemic zone collateral blood flow, and infarct size reduction compared with intra-aortic balloon counterpulsation and reperfusion alone. Methods and Results. Eighteen dogs were instrumented with regional myocardial function sonomicrometers in the ischemic and control zones. The left anterior descending coronary artery just distal to the first diagonal branch was instrumented with a silk snare and Doppler flow probe. Additionally, pressure catheters were placed in the left atrial appendage, left ventricular apex, and ascending aorta for hemodynamic measurements. Regional myocardial blood flow was determined by using 15-gm radioactive microspheres. Measurements were made in the control state, immediately after coronary occlusion, at 1 and 2 hours after coronary occlusion, with reperfusion, and 1 hour after reperfusion. In treated animals, left ventricular assistance was maintained during the entire period of occlusion and reperfusion. The Hemopump was associated with a significant decrease in left ventricular systolic and diastolic pressure, whereas mean arterial pressure was maintained. Intra-aortic balloon counterpulsation resulted in no significant changes in left ventricular systolic pressure and a modest decrease in left ventricular diastolic

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Canine Infarction Model

Background. It has been suggested that left ventricular unloading at the time of reperfusion provides superior infarct salvage over reperfusion alone. The purpose of this study was to show that the Hemopump transvalvular axial-flow left ventricular assist device provides superior left ventricular unloading, ischemic zone collateral blood flow, and infarct size reduction compared with intra-aort...

متن کامل

Role of percutaneous coronary minimalist intervention in the management of acute ST-segment elevation myocardial infarction.

1. Smalling RW, Cassidy DB, Barrett R, et al. Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model. Circulation 1992;85:1152–9. 2. Henriques JP, Remmelink M, Baan J Jr., et al. Safety and...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

What is the optimal anticoagulation in patients with a left ventricular assist device?

A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether there is an optimal antithrombotic management for patients supported with axial-flow left ventricular assist devices (LVADs). Altogether, more than 758 papers were found using the reported search, of which 17 represented the best evidence to answer the clinical question. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005