Automated cuff pressure modulation: a novel device to reduce endotracheal tube injury.
نویسندگان
چکیده
OBJECTIVE To assess whether dynamically modulating endotracheal tube (ETT) cuff pressure, by decreasing it during each ventilatory cycle instead of maintaining a constant level, would reduce the extent of intubation-related laryngotracheal injury. DESIGN Single-blind, randomized controlled animal study using a previously validated live porcine model of accelerated intubation-related tracheal injury. SETTING Animal research facility. PATIENTS Ten piglets (weight, 16-20 kg each) were anesthetized and underwent intubation using a cuffed ETT. INTERVENTIONS The animals were randomized into the following 2 groups: 5 pigs had a novel device to modulate their cuff pressure from 25 cm H₂O during inspiration to 7 cm H₂O during expiration, and 5 pigs had a constant cuff pressure of 25 cm H₂O. Both groups underwent ventilation under hypoxic conditions for 4 hours. MAIN OUTCOME MEASURE Laryngotracheal mucosal injury after blinded histopathological assessment. RESULTS The modulated-pressure group showed significantly less overall laryngotracheal damage than the constant-pressure group (mean grades, 1.2 vs 2.1; P < .001). Subglottic damage and tracheal damage were significantly less severe in the modulated-pressure group (mean grades, 1.0 vs 2.2; P < .001, and 1.9 vs 3.2; P < .001, respectively). There was no significant difference in glottic or supraglottic damage between the groups (P = .06 and .27, respectively). CONCLUSIONS This novel device reduces the risk of subglottic and tracheal injury by modulating ETT cuff pressure in synchronization with the ventilatory cycle. This finding could have far-reaching implications for reducing the risk of airway injury in patients undergoing long-term intubation. Further clinical study of this device is warranted.
منابع مشابه
Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملبررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی
Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...
متن کاملAssessment of aspiration risk from dynamic modulation of endotracheal tube cuff pressure.
OBJECTIVES/HYPOTHESIS To assess the risk of aspiration using a novel valve circuit that dynamically modulates endotracheal tube cuff pressure during the ventilatory cycle using bench and live animal models. STUDY DESIGN Animal model. METHODS The bench model consisted of a cuffed endotracheal tube inserted into an artificial trachea. Leakage of liquid around the cuff was measured after 4 hou...
متن کاملStudy of endotracheal tube cuff pressure and time of measurement among intensive care units patients
Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...
متن کاملEffect of body position and head of bed angle on intra-abdominal and endotracheal tube cuff pressure in mechanically ventilated patients
Introduction: Changing position is one of the typical nursing care in intensive care units. This study aimed to investigate the effect of body positioning on intra-abdominal pressure and endotracheal tube cuff pressure and their relationship with each other in patients undergoing mechanical ventilation Materials and Methods: This was a before-after clinical trial study performed on 70 patients ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of otolaryngology--head & neck surgery
دوره 137 1 شماره
صفحات -
تاریخ انتشار 2011