Reliability of ankle dorsiflexion passive range of motion measurements obtained using a hand-held goniometer and Biodex dynamometer in stroke patients
نویسندگان
چکیده
[Purpose] This study investigated the reliability of ankle dorsiflexion passive range of motion (DF-PROM) measurements obtained using a goniometer and Biodex dynamometer in stroke patients. [Subjects] Fifteen stroke patients participated in this study. [Methods] Ankle DF-PROM was assessed using a goniometer and Biodex dynamometer. Ankle DF-PROM was measured during two sessions with 7 days between tests. Intraclass correlation coefficient, standard error of measurement, and minimal detectable change values were used to assess the reliability of measurements obtained using both instruments. [Results] The intra-rater reliability for ankle DF-PROM using the goniometer was moderate and good for the two raters, while using the Biodex dynamometer, it was good for both raters. Inter-rater reliability using the goniometer was moderate; using the Biodex, it was good. [Conclusion] Both intra- and inter-reliability measurements of ankle DF-PROM were higher using a Biodex dynamometer than with a goniometer.
منابع مشابه
The Relationship Between Muscle Strength and Range of Motion in Lower Extremity, and Balance and Risk of Falling in the Elderly
Background: The present study examined the relationship between muscle strength and range of motion in the lower extremity, and balance and risk of falling in the elderly. Methods: This cross-sectional study was conducted on healthy elderly (mean±SD age: 65.64±4.95 y) in Rasht City, Iran. The study participants were 65 healthy male elderly who met the stud inclusion criteria. They were selecte...
متن کاملتأثیر والگوس پویای زانو حین اسکات بالای سر بر قدرت و دامنه حرکتی مفاصل دیستال و پروگزیمال زانوی بسکتبالیستها
Objective: The purpose of this study was to investigate the effect of dynamic knee valgus during overhead squat, on hip and ankle joints muscle strength and range of motion in basketball players. Methods: In this study, 35 healthy basketball players (with the mean age of 20.98± 1.99, height 183.27 ± 6.64 cm and mass 75.31 ± 9.24 kg), in the control group (n = 18) and dynam...
متن کاملRange of Motion and Stiffness of the Pediatric Ankle and Implications for Current ATDs
Pediatric anthropomorphic test devices (ATDs) do not contain instrumentation below the knee, making it difficult to directly measure forces applied to the leg during impact. The goal of this study was to evaluate the anthropometric characteristics and stiffness response of the pediatric ankle in order to gain valuable data for the development of a more biofidelic ATD ankle. Forty-two children b...
متن کاملComparison between the Short Term and Durability Effects of Proprioceptive Neuromuscular Facilitation Exercise and Instrument Assisted soft Tissue Mobilization Technique on Ankle-Dorsiflexion Range of Motion
Introduction: Reduced lower extremity range of motion and movement leads to a decrease in movement efficiency; accordingly, it is vital to maintain the range of motion to prevent damage and improve functions. The purpose of this study was to compare the short term and durability effects of Instrument Assisted Soft Tissue Mobilization (IASTM) and Proprioceptive Neuromuscular Facilitation (PNF) t...
متن کاملEffects of using an unstable inclined board on active and passive ankle range of motion in patients with ankle stiffness
[Purpose] The present study assessed the effects of using an unstable inclined board on the active and passive ankle range of motion in patients with ankle stiffness. [Subjects] The study included 10 young female patients with ankle stiffness. [Methods] The patients were divided into the following two groups: a group that performed ankle dorsiflexion stretching exercises using a wooden inclined...
متن کامل