Magnetic Resonance Imaging Findings in a Dual Taper, Modular Total Hip Arthroplasty

نویسندگان

  • Matthew F. Koff
  • Stephanie L. Gold
  • Brett Lurie
  • Danyal H. Nawabi
  • Geoffrey Westrich
  • Hollis G. Potter
چکیده

confirmed by histologic analysis, around a dual taper modular hip arthroplasty. The coronal MAVRIC MR image demonstrates a synovial thickness of 22mm (white arrowheads). Decompression of ALTR into the iliopsoas bursa is indicated with a white arrow. This subject was given an ALVAL score of 10. 6266 Magnetic Resonance Imaging Findings in a Dual Taper, Modular Total Hip Arthroplasty Matthew F. Koff, Stephanie L. Gold, Brett Lurie, Danyal H. Nawabi, Geoffrey Westrich, and Hollis G. Potter Hospital for Special Surgery, New York, NY, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach

Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...

متن کامل

Fretting and corrosion in modular-neck total hip arthroplasty femoral stems.

BACKGROUND During total hip arthroplasty, use of a modular femoral neck on a stemmed implant allows optimization of neck anteversion, length, and offset, resulting in more accurate balance. We performed a retrospective analysis of a consecutive cohort of patients who had undergone total hip arthroplasty with a modular-neck hip system with ceramic-on-ceramic bearings. METHODS We reviewed the r...

متن کامل

Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

BACKGROUND Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. METHODS This was a multicenter retrospective case serie...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013