Mebendazole selective membrane sensor and its application to pharmaceutical analysis.
نویسندگان
چکیده
A PVC membrane sensor for the selective determination of mebendazole (MBZ) was fabricated. The sensor is based on an ion association of MBZ with silicotungstic acid (STA) as ion pair and bis(2-ethylhexyl)phthalate (BEP) as the plasticizing agent in a PVC matrix. The sensor showed a linear response for MBZ for a concentration range 1.0x10(-6)-5.0x10(-2) M with a Nernstian slope of 55.8 mV/decade (limit of detection 6.3x10(-7) M) in the pH range 4-7. It has a fast response time of <30 s. The sensor showed a very good selectivity for MBZ with respect to a large number of ions. The direct determination of MBZ in pharmaceutical formulations gave results that compare well with the data obtained from the standard method.
منابع مشابه
A Green Potentiometric Application for Selective Monitoring of Doxylamine Succinate Dissolution Profile in Combined Dosage Form
"Green analytical chemistry" (GAC) succeeded to become an eco-friendly environmental crucial area in the field of analytical chemistry targeting at the chemical processes' and products' optimization regarding to material consumption, generation of waste and intrinsic safety, toxicity and environmental burdens. For an expressive comparison, an electro-analytical in-line potentiometric selective ...
متن کاملN-phenylaza-15-crown-5 as Ionophore in PVC-Matrix for Fe2+ - Selective Sensor
The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملPerformance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations
A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...
متن کاملPotentiometric Method to Determine Montelukast Sodium in its Tablets with In-line Monitoring of its Dissolution Behaviour
Direct drug determination without any pervious treatment steps is the most environmentally friendly method of analysis. Traditional analysis methods usually involve a pre-treatment step before analysis and this consumes time and organic solvents. This work describes direct potentiometric method by using ion selective electrode to determine Montelukast Sodium in its pure drug substance and in ta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2007