Pulsed Fourier - Transform NQR of ' 4 N with a dc SQUID 27 JUt V 1992
نویسنده
چکیده
M. D. Hiirlimann, " ' C. H. Pennington, " " N. Q. Fan, ' ' John Clarke, " ' " A. Pines, ' ' and E. L. Hahn ' (])Department of Physics, University of CaliforniaB, erkeley, BerkeleyC, alifornia 94720 (2)Department of Chemistry, University of California, Berkeley, Berkeley, California 94720 (3)Materials Sciences DitisionLa, wrence Berkeley Laboratory, Berkeley, California 94720 (Received 22 May 1992)
منابع مشابه
SQUID detected NMR and NQR
Ž . The dc Superconducting QUantum Interference Device SQUID is a sensitive detector of magnetic flux, with a typical flux noise of the order 1 mF Hz at liquid helium temperatures. Here F s"r2 e is the flux quantum. In our NMR or 0 0 NQR spectrometer, a niobium wire coil wrapped around the sample is coupled to a thin film superconducting coil deposited on the SQUID to form a flux transformer. W...
متن کاملLow Frequency Nuclear Quadrupole Resonance with SQUID Amplifiers*
The dc SQ U ID (Superconducting QUantum Interference Device) can be configured as an ampli fier of spin-echos with a noise temperature of approximately 10 mK (f/1 MHz) at an operating temperature of 1.5 K. A Fourier transform spectrometer based on a SQ U ID with a superconducting input circuit and operated in a flux-locked loop is used to obtain nuclear quadrupole resonance (NQR) spectra in a ...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کاملDevelopment of Low Frequency Pulsed NQR/NMR Spectrometer
An FPGA based NQR spectrometer has been designed for detection of N nuclei. The digital circuits required for NQR spectrometer i.e Pulse Programmer, DDS, digital receiver have been built inside FPGA. Combining FPGA chip with analog components, NQR spectrometer has been developed. N from NaNO2 is observed using same spectrometer. By adding a permanent magnet of uniform field NMR signal of proton...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کامل