Microextraction Methods for Preconcentration of Aluminium in Urine Samples
نویسندگان
چکیده
Background: Analysis of aluminium (Al) in urine samples is required in management of a number of diseases including patients with renal failure. This work aimed to present dispersive liquid-liquid microextraction (DLLME) and ultrasound-assisted emulsification microextraction (USAEME) methods for the preconcentration of ultratrace amount of aluminum in human urine prior to its determination by a graphite furnace atomic absorption spectrometry (GFAAS). Methods: The microextraction methods were based on the complex formation of Al with 8-hydroxyquinoline. The effect of various experimental parameters on the efficiencies of the methods and their optimum values were studied. Results: Under the optimal conditions, the limits of detection for USAEME-GFAAS and DLLME-GFAAS were 0.19 and 0.30 ng mL, respectively and corresponding relative standard deviations (RSD, n=5) for the determination of 40 ng mL Al were 5.9% and 4.9%. Conclusion: Both methods could be successfully used to the analysis of ultra trace concentrations of Al in urine samples of dialysis patients. A r t i c l e I n f o Article History: Received: 20 January 2016 Accepted: 20 February 2016 ePublished: 30 June 2016
منابع مشابه
Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop as an Efficient Preconcentration Method for Spectrophotometric Determination of Aluminium
A rapid, simple, and sensitive dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFOD) method coupled with UV–Vis spectrophotometry has been applied for the extraction and determination of trace amounts of aluminium. The aluminium was extracted from the aqueous media containing aluminon and cetyltrimethylammonium bromide (CTAB). After rapid injecti...
متن کاملComparison of Two Liquid-Liquid Microextractions for the Detection of Crocin in the Saffron and Biological Samples Using UV- Vis Spectrophotometry
In this work, two approaches based on Dispersive Liquid-Liquid MicroExtraction (DLLME) and Dispersive Liquid-Liquid MicroExtraction based on Solidification of Floating Organic Drop (DLLME-SFO) were compared for the extraction and preconcentration of crocin from saffron and biological samples. Different DLLME and DLLME-SFO parameters influencing the extraction efficiency were studied and opt...
متن کاملDevelopment of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples
A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...
متن کاملOptimized preconcentration of Imatinib using dispersive liquid-liquid microextraction coupled with HPLC-UV
Background: Imatinib is an antineoplastic agent acting as a tyrosine kinase inhibitor to treat cancer such as lymphoblastic leukemia. The dosage of the anticancer drugs plays a critical role in the survival of the patients. For this reason, the patient's plasma and urine samples should be monitored to obtain the necessary information regarding the toxicity of the drug. In this study, the applic...
متن کاملPrediction of the Trace Amounts of Atomoxetine in Biological Samples using optimized solvent bar microextraction technique coupled with HPLC-UV
Atomoxetine, an attention-deficit/hyperactivity disorder (ADHD) agent , has severe adverse effects, which even causes suicidal ideation in patients and when combined with other drugs such as monoamine oxidase inhibitors or in patients with cardiovascular disorders or pheochromocytoma, it can be fatal. In order to monitor the trough level of the drug, sensitive analytical methods are in demand.T...
متن کامل