BACKGROUND Automated peritoneal dialysis (APD) has been increasingly used in recent years. Our purpose was to investigate whether the good preservation of residual renal function (RRF) that has been reported in patients on continuous ambulatory peritoneal dialysis (CAPD) is also observed in APD. METHODS RRF was determined and compared prospectively over 1 year in two groups of peritoneal dialysis (PD) patients: 18 consecutive new patients starting on APD (12 continuous cyclic peritoneal dialysis (CCPD) patients and six nightly intermittent peritoneal dialysis (NIPD) patients) and 18 selected patients who had started on CAPD at the same time and were matched for baseline characteristics. RRF was assessed on normalized creatinine clearance (ml/min/1.73 m2) measured before the start of PD, at 6 months, and at 1 year. Wilcoxon's rank sum test was used to compare differences between the two groups. RESULTS Creatinine clearance (ClCr) was 6.1 ml/min in the APD group and 6 ml/min in the CAPD group at the start of PD. The monthly rate of ClCr decrease was significantly higher in the APD group: -0.28 ml/min vs -0.1 ml/min (P = 0.04) at 6 months and -0.26 ml/min vs -0.13 ml/min (P = 0.005) at 1 year. RRF decreased at the same rate in patients treated with NIPD or CCPD. The daily instilled volume of 3.86% glucose dialysis solution (l/day) was higher in APD patients than in CAPD patients: 2.5 vs 0 at 6 months and 1 year but there was no significant difference in ultrafiltration rate (l/day) between APD and CAPD patients at these timepoints: 0.53 vs 0.6 and 0.88 vs 0.7 respectively. There was no difference between the two groups in body weight and blood pressure, which remained stable in both groups throughout the study period. CONCLUSIONS RRF declined rapidly in APD patients whereas it was well preserved in CAPD patients. This may be explained by the less stable fluid and osmotic load together with the intermittent nature of APD and the larger use of hypertonic dialysate. RRF should be closely monitored in APD patients in order to adjust PD prescriptions and maintain adequacy.
منابع مشابه
Developing a Device for Automated Peritoneal Dialysis
Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...
متن کاملEffectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study
Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...
متن کاملResidual renal function in children treated with continuous ambulatory peritoneal dialysis or automated peritoneal dialysis--a preliminary study.
Our study assessed the influence of mode of dialysis [continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD)] on residual renal function (RRF). The study retrospectively examined 30 children [15 on CAPD, mean age: 8.85 +/- 5.15 years; and 15 on APD, mean age: 10.17 +/- 3.63 years (nonsignificant)], followed for at least 12 months, for whom these methods were ini...
متن کاملThe Comparative Survey of Life Quality in Renal Transplant Recipients, Peritoneal Dialysis, and Hemodialysis Patients in Kerman in the Year 2013
Background & Objective: According to the World Health Organization (WHO) definition, quality of life is a state of complete physical, mental, and social health not merely the absence of the disease. End stage renal disease and its treatment affect patients' quality of life. Therefore, the present study surveyed the quality of life in renal transplant recipients, hemodialysis, and peritoneal di...
متن کاملSpirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis
Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50 pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 15 7 شماره
صفحات -
تاریخ انتشار 1999