Quantitation of aortic insufficiency using a catheter-tip velocity transducer.
نویسندگان
چکیده
Bidirectional instantaneous aortic root blood flow was measured in 18 patients with aortic insufficiency (AI) using a catheter-tip velocity transducer. The magnitude of AI was quantitated by determining total forward systolic flow from the area of the flow velocity curve above the zero baseline and regurgitant diastolic flow from the curve area below the baseline. Effective forward flow (stroke volume) was calculated as the difference between total forward systolic flow and regurgitant diastolic flow. Regurgitant fraction was determined as the ratio of regurgitant flow to total forward flow. These data were compared with conventional angiographic estimates (1+ to 4+) of the degree of insufficiency. Velocity transducer determination of regurgitant fraction was 26% in the patient with 1+ AI, 37% (31-48%) in 2+ AI, 49% (35-61%) in 3+ AI and 72% in 4+ AI (regurgitant fraction vs angiographic grade, r = 0.84). Regurgitant flow per diastole was 9 ml in the patient with 1+ AI, 39 ml (20-49 ml) in 2+ AI, 57 ml (31-102 ml) in 3+ AI and 183 ml (143 and 223 ml) in 4+ AI (regurgitant diastolic flow vs angiographic grade, r = 0.73). Good correlation (r = 0.90) was found between values of regurgitant flow obtained from the left ventriculogram and those obtained using the velocity transducer. Although the overall association was good, wide, variability in regurgitant fraction and regurgitant flow was found in the 15 patients with 2+ to 3+ AI. These results suggest that the electromagnetic velocity catheter offers a simple technique for quantitating AI.
منابع مشابه
Use of catheter-tip velocity--pressure transducer to evaluate left ventricular function in man: effects of intravenous propranolol.
A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...
متن کاملUse of Catheter-tip. Velocity-Pressure Transducer
A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...
متن کاملInstantaneous Blood Flow Responses
Variable hemodynamic responses to positive end-expiratory pressure (PEEP) with spontaneous ventilation have been reported. To clarify these responses, 15 awake patients were studied using a catheter-tip velocity transducer to record phasic aortic root blood flow continuously before, during and after PEEP (10 cm H20) applied with a face mask. Central blood volume and effective ventricular fillin...
متن کاملAn electromagnetic catheter-flowmeter.
An electromagnetic flowmeter incorporated into a catheter is described. The catheter is introduced into the aorta via the femoral artery. The flow sensor is located some distance below the catheter tip and is sensitive to flow at right angles to the catheter. A crater-like elevation at one end of the transducer lumen permits funnel-like connection of the transducer to the ostium of an aortic br...
متن کاملTurbulent blood flow in humans: its primary role in the production of ejection murmurs.
To clarify the postulate that turbulence may produce ejection murmurs, point velocity and sound were measured in the ascending aorta of 13 subjects: six with normal aortic valves, six with aortic valvular disease, and one with a Bjork-Shiley prosthetic aortic valve. Velocity was measured with a catheter-tip hot film anemometer probe, and sound was measured with a catheter-tip micromanometer. Ej...