Endotoxins in ophthalmic viscosurgical devices.
نویسندگان
چکیده
PURPOSE To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). METHODS The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. RESULTS 16 OVDs (Amvisc, Amvisc Plus, Biolon, Coatel, Healon, Healon GV, Healon, HPMC Ophtal L, Microvisc, Microvisc Plus, Ocucoat, Provisc, Rayvisc, Viscoat, Visco Shield 2%, Visko 1.4%) had an EC under 1.2 endotoxin units/mL, five (Adatocel, HPMC Ophtal H, LA Gel, Viscorneal, Viscorneal Plus) had an EC > or = 1.2 and < or = 24 EU/ml, and four (Biocorneal, Dispasan also named Ophthalin, Dispasan Plus, Visko 1%) had an EC of > 24 EU/ml. DISCUSSION To avoid viscoelastic-related inflammatory or immunological reactions, the use of pure OVDs is recommended, especially for surgical procedures with an inherent possibility of leaving viscoelastic remnants in the eye (e.g., cataract surgery, visco-canalostomy or penetrating keratoplasty).
منابع مشابه
Bacterial endotoxin detection in hyaluronic acid-based medical devices.
A simple and rapid method has been developed for testing bacterial endotoxin in hyaluronic acid (HA)-based medical devices. High-molecular-weight HA (HMW HA) in solution or HA-based medical devices was digested by the enzyme hyaluronidase to reduce solution viscosity by truncating the long chains of HA and to test for bacterial endotoxin. The bacterial endotoxin level was detected and measured ...
متن کاملA clinical comparison between DisCoVisc and 2% hydroxypropylmethylcellulose in phacoemulsification: a fellow eye study
OBJECTIVE This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized techniqu...
متن کاملComparative Evaluation of Efficacy and Safety of Ophthalmic Viscosurgical Devices in Phacoemulsification
Background: Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. Methods: Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsifica...
متن کاملComparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification [ISRCTN34957881]
BACKGROUND Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. METHODS Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsifica...
متن کاملCataract Surgery Eyes with Zonular Weakness
D uring the last decade, the intraoperative use of various devices—including those for the shortand long-term support of the pupil, capsule, and zonules—has revolutionized the treatment of eyes with zonular laxity or focal zonular absence. Intraoperatively, surgeons use both temporary and permanent implantable devices as well as ophthalmic viscosurgical devices (OVDs). The combination of these ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2003