Real and Pseudoaccommodation in Accommodative Lenses

نویسندگان

  • Ioannis G. Pallikaris
  • Georgios A. Kontadakis
  • Dimitra M. Portaliou
چکیده

In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were designed to fill this gap and provide satisfactory vision for all distances by restoring some degree of "pseudoaccommodation." Pseudo accommodative capability can be linked to monofocal IOL's as well but the results are not satisfactory enough to fully support unaided near vision. Pseudoaccommodation is a complex phenomenon that can be attributed to several static (i.e., pupil size, against-the-rule cylindrical refractive error, multifocality of the cornea) and dynamic (i.e., anterior movement of the implant itself) factors. Objective measurement of the accommodative capability offered by the accommodative IOLs is extremely difficult to obtain, and different methods such as autorefractometers, retinoscopy, and ultrasound imaging during accommodative effort, ray tracing, or pharmacological stimulation have been developed but the results are sometimes inconsistent. Despite the difficulties in measuring accommodation, accommodative IOLs represent the future in the attempt to successfully "cure" presbyopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accommodative intraocular lenses: where are we and where we are going

Presbyopia still remains the last frontier of refractive surgery. Its surgical management is under constant evolution due to the limitations that exist today with respect to its management, which is probably in relation with the multifactorial basis in which presbyopia is clinically developed in the human. Until currently, virtually all surgical techniques that have been proposed for its correc...

متن کامل

Aberrometry in patients implanted with accommodative intraocular lenses.

PURPOSE To evaluate the objective accommodative response, change of aberrations, and depth of focus in eyes implanted with the Crystalens accommodative intraocular lens (IOL) at different accommodative demands. DESIGN Prospective, observational study. METHODS Eleven cataract patients (22 eyes) who underwent implantation of a Crystalens accommodative IOL, and control groups of 9 normal subje...

متن کامل

Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses

PURPOSE To determine the amplitude of pseudoaccommodation and higher-order aberrations with three types of implanted monofocal intraocular lenses (IOLs): aspheric yellow (IQ); spheric yellow (NT); and spheric clear (AT). SETTING Department of Ophthalmology, Nara Medical University, Nara, Japan. METHODS We studied 60 patients who underwent small incision phacoemulsification with the implanta...

متن کامل

Myopic children show insufficient accommodative response to blur.

PURPOSE The study was performed to establish the relationship between the slope of the accommodative response function and refractive error in children. METHODS Using an autorefractor, accommodative responses were measured in children under the following conditions. The subjects wore their best subjective refraction to view targets (a 3 x 3 array of 20/100 letters) displayed at seven distance...

متن کامل

Optical aberrations, accommodation, and visual acuity with a bioanalogic continuous focus intraocular lens after cataract surgery

Purpose To evaluate the visual outcomes, pseudoaccommodation, and wavefront aberrometry after implantation of Wichterle IOL-Continuous Focus (WIOL-CF®, Gelmed International, Kamenne Zehrovice, Czech Republic) by i-Trace aberrometry. Methods In this retrospective interventional case series study, after cataract surgery with implantation of accommodative WIOL-CF®, the patients were evaluated wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011