NICMOS Temperature Monitoring
نویسندگان
چکیده
The NICMOS detectors are sensitive to the operating temperature. During the Cycle 7 era, NICMOS was cooled through cryogenic solid nitrogen. This resulted in an operating temperature varying from 61K to 62.5K before the nitrogen was exhausted. Using the new NICMOS Cooling System (NCS), the nominal temperature is significantly more stable, but at a higher temperature, 77.15 K. The stability of the dewar temperature is maintained through manual changes to the NCS temperature set-point. The achieved thermal stability is ∼0.1K. We describe the temperature history, the NICMOS temperature dependencies and remaining temperature fluctuations.
منابع مشابه
NICMOS Temperature - specific Darks
The various components of NICMOS dark images have been modeled and combined to make synthetic dark calibration files which are intended for use with observations in a temperature range from 61 to ~75 K, currently available only for camera 2, with cameras 1 and 3 to follow in a few months. The amplifier glow and the true linear dark current have been constructed as temperature-independent quanti...
متن کاملNICMOS Focus and HST Breathing
The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the...
متن کاملNICMOS optical aberrations: coma and astigmatism
Coma and astigmatism of NICMOS cameras have been derived using phase retrieval analysis of the data from the NICMOS focus monitoring program. Analysis of these aberrations has revealed that y-coma in all three camera experienced a systematic change over the NICMOS lifetime in Cycles 7 and 7a. A similar variation has been found for x-astigmatism in camera 2. In camera 3, the x-astigmatism increa...
متن کاملLong-term trends in the NICMOS Camera 2 obscuration pattern and aberrations
Phase retrieval measurements of well-exposed NICMOS Camera 2 star images show that long-term changes occurred in coma and the cold mask position over the 1997-1998 lifespan of the instrument. These caused time-dependent variations in the PSF diffraction pattern, notably the shape of the Airy rings and the positions of bands in the diffraction spikes. These effects are evident in both direct and...
متن کاملBright Earth Persistence in NICMOS
We report the presence of image persistence in NICMOS data due to prior saturation of the array by the bright Earth as well as an algorithm to remove its impact. BEP (Bright Earth Persistence) may occur when ACS and NICMOS are used in parallel, and the data dump of ACS delays the insertion of the NICMOS filter blank as long as 6 minutes beyond the Bright Earth avoidance angle. We have construct...