UK Renal Registry 16th annual report: chapter 10 haemoglobin, ferritin and erythropoietin amongst UK adult dialysis patients in 2012: national and centre-specific analyses.
نویسندگان
چکیده
INTRODUCTION Anaemia treatment in chronic kidney disease (CKD) patients has changed dramatically since the implementation of erythropoietin stimulating agents (ESAs) and has shifted the emphasis from treating severe anaemia in dialysis patients to preventing anaemia. The aim of this chapter is to determine the extent to which the UK Renal Association (RA) and National Institute for Health and Care Excellence (NICE) guidelines for anaemia management are met in the UK. METHODS Quarterly data were obtained for haemoglobin (Hb) and factors that influence Hb from UK renal centres for the incident and prevalent renal replacement therapy (RRT) cohorts for 2012. RESULTS In the UK, in 2012, 51% of patients commenced dialysis therapy with Hb 100 g/L (median Hb 100 g/L). Of patients in the early presentation group, 54% started dialysis with Hb 100 g/L whilst 34% of patients presenting late started dialysis with Hb 100 g/L. The UK median Hb of haemodialysis (HD) patients was 112 g/L, with 82% of patients having Hb 100 g/L. The median Hb of peritoneal dialysis (PD) patients in the UK was 114 g/L, with 85% of patients having Hb 100 g/L. The median ferritin in HD patients in the UK was 431 µg/L and 95% of HD patients had a ferritin 100 µg/L. In EW&NI the median ferritin in PD patients was 285 µg/L (IQR 164-466) with 88% of PD patients having a ferritin 100 µg/L. In EW&NI the median ESA dose was higher for HD than PD patients (7,248 vs. 4,250 IU/week). The percentage of patients treated with an ESA and having Hb >120 g/L ranged between centres from 7-39% for HD and from 0-33% for PD. CONCLUSIONS There was poor correlation between median Hb achieved and median ferritin and ESA usage across the EW&NI centres. There was also a significant variation between centres in the percentages of patients treated with an ESA and having Hb >120 g/L. © 2014 S. Karger AG, Basel.
منابع مشابه
UK Renal Registry 15th annual report: Chapter 6 haemoglobin, ferritin and erythropoietin amongst UK adult dialysis patients in 2011: national and centre-specific analyses.
BACKGROUND The UK Renal Association (RA) and National Institute for Health and Care Excellence (NICE) have published Clinical Practice Guidelines which include recommendations for management of anaemia in established renal failure. AIMS To determine the extent to which the guidelines for anaemia management are met in the UK. METHODS Quarterly data were obtained for haemoglobin (Hb) and fact...
متن کاملUK Renal Registry 13th Annual Report (December 2010): Chapter 9: haemoglobin, ferritin and erythropoietin amongst UK adult dialysis patients in 2009: national and centre-specific analyses.
BACKGROUND The UK Renal Association (RA) and National Institute for Health and Clinical Excellence (NICE) have published Clinical Practice Guidelines which include recommendations for management of anaemia in established renal failure. AIMS To determine the extent to which the guidelines for anaemia management are met in the UK. METHODS Quarterly data were obtained regarding haemoglobin (Hb...
متن کاملUK Renal Registry 19th Annual Report: Chapter 7 Haemoglobin, Ferritin and Erythropoietin amongst UK Adult Dialysis Patients in 2015: National and Centre-specific Analyses.
BACKGROUND The diagnosis and management of anaemia in chronic kidney disease and the standards to be achieved have been detailed in the UK Renal Association Anaemia of CKD guidelines. AIMS To determine the attainment of standards for anaemia management in the UK. METHODS Quarterly data were obtained for haemoglobin (Hb) and factors that influence Hb from renal centres in England,Wales, Nort...
متن کاملUK Renal Registry 16th annual report: chapter 12 biochemical variables amongst UK adult dialysis patients in 2012: national and centre-specific analyses.
INTRODUCTION The UK Renal Association clinical practice guidelines include clinical performance measures for biochemical variables in dialysis patients. The UK Renal Registry (UKRR) annually audits dialysis centre performance against these measures as part of its role in promoting continuous quality improvement. METHODS Cross sectional performance analyses were undertaken to compare dialysis ...
متن کاملUK Renal Registry 18th Annual Report: Introduction.
The UK Renal Registry (UKRR) continues to provide a national source of NHS healthcare data on patients dependent on renal replacement therapy (RRT) across the four nations. Using electronic reporting and substantial integration across the 71 adult and 13 paediatric renal centres independent audit and analysis of dialysis and transplant activity and care across the UK is provided. The UKRR is pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephron. Clinical practice
دوره 125 1-4 شماره
صفحات -
تاریخ انتشار 2013