Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking.
نویسندگان
چکیده
Three-dimensional (3D) soft tissue tracking is of interest for monitoring organ motion during therapy. Our goal is to assess the tracking performance of a curvilinear 3D ultrasound probe in terms of the accuracy and precision of measured displacements. The first aim was to examine the depth dependence of the tracking performance. This is of interest because the spatial resolution varies with distance from the elevational focus and because the curvilinear geometry of the transducer causes the spatial sampling frequency to decrease with depth. Our second aim was to assess tracking performance as a function of the spatial sampling setting (low, medium or high sampling). These settings are incorporated onto 3D ultrasound machines to allow the user to control the trade-off between spatial sampling and temporal resolution. Volume images of a speckle-producing phantom were acquired before and after the probe had been moved by a known displacement (1, 2 or 8 mm). This allowed us to assess the optimum performance of the tracking algorithm, in the absence of motion. 3D speckle tracking was performed using 3D cross-correlation and sub-voxel displacements were estimated. The tracking performance was found to be best for axial displacements and poorest for elevational displacements. In general, the performance decreased with depth, although the nature of the depth dependence was complex. Under certain conditions, the tracking performance was sufficient to be useful for monitoring organ motion. For example, at the highest sampling setting, for a 2 mm displacement, good accuracy and precision (an error and standard deviation of <0.4 mm) were observed at all depths and for all directions of displacement. The trade-off between spatial sampling, temporal resolution and size of the field of view (FOV) is discussed.
منابع مشابه
Temperature Mapping Using Ultrasound Digital Images
Introduction: The success of hyperthermia depends on the accuracy of the temperature monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes were determined by computing the speckle displacement in the ultrasound digital images. Speckle tracking algorithm was used to compute the displacement. Materials and Methods: The experiment was perf...
متن کامل4D ultrasound speckle tracking of intra-fraction prostate motion: a phantom-based comparison with x-ray fiducial tracking using CyberKnife.
This study investigates the use of a mechanically-swept 3D ultrasound (3D-US) probe for soft-tissue displacement monitoring during prostate irradiation, with emphasis on quantifying the accuracy relative to CyberKnife® x-ray fiducial tracking. An US phantom, implanted with x-ray fiducial markers was placed on a motion platform and translated in 3D using five real prostate motion traces acquired...
متن کاملDesign, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging
This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...
متن کاملThree dimensional motion compensation for real-time MRI guided focused ultrasound treatment of abdominal organs
Purpose/Introduction MR-guided High Intensity Focused Ultrasound (HIFU) for the ablation of tumors in abdominal organs under freebreathing conditions poses two challenges: 1) The current organ position in 3D-space must be continuously tracked in order to reposition the focal point of the HIFU-device to avoid undesired tissue damage. 2) Phase variations due to the organ displacement must be corr...
متن کاملPotential use of ultrasound speckle tracking for motion management during radiotherapy: preliminary report.
We prospectively evaluated real-time ultrasound speckle tracking for monitoring soft tissue motion for image-guided radiotherapy. Two human volunteers and 1 patient with a proven hepatocellular carcinoma, who was being prepared for radiation therapy treatment, were scanned using a clinical ultrasound scanner modified to acquire and store radiofrequency signals. Scans were performed of the liver...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 52 18 شماره
صفحات -
تاریخ انتشار 2007