Pii: S0730-725x(02)00526-x

نویسندگان

  • Eugene G. Kholmovski
  • Alexei A. Samsonov
  • Dennis L. Parker
چکیده

There is considerable similarity between proton density-weighted (PDw) and T2-weighted (T2w) images acquired by dual-contrast fast spin-echo (FSE) sequences. The similarity manifests itself in image space as consistency between the phases of PDw and T2w images and in k-space as correspondence between PDw and T2w k-space data. A method for motion artifact reduction for dual-contrast FSE imaging has been developed. The method uses projection onto convex sets (POCS) formalism and is based on image space phase consistency and the k-space similarity between PDw and T2w images. When coupled with a modified dual-contrast FSE phase encoding scheme the method can yield considerable artifact reduction, as long as less than half of the acquired data is corrupted by motion. The feasibility and efficiency of the developed method were demonstrated using phantom and human MRI data. © 2002 Elsevier Science Inc. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0730-725x(02)00485-x

The influence of Gd-DTPA on T1-weighted (T1W) proton MR spectra has been investigated in 19 patients with histologically verified low (n 13) or high-grade (n 6) gliomas. Repeat measurements were performed on 9 patients (7 low-grade and 2 high-grade), with 28 examinations performed in total. Comparison of spectra obtained before and after 0.2 mmol/kg Gd-DTPA showed contrast agent induced broaden...

متن کامل

Pii: S0730-725x(00)00154-5

We describe an MR-compatible ventilator that is computer controlled to generate a variety of breathing patterns, to minimize image degrading effects of breathing motion, and to support delivery of gas anesthesia and experimental inhalational gases. A key feature of this ventilator is the breathing valve that attaches directly to the endotracheal tube to reduce dead volume and allows independent...

متن کامل

Pii: S0730-725x(02)00507-6

Susceptibility-induced perturbation of the static magnetic field by the human body during magnetic resonance imaging (MRI) leads to undesirable artifacts as well as valuable physiological information, as in functional MRI. The ability to calculate these perturbations for a multi-tissue human body model provides a powerful tool in designing hardware and acquisition methods for reducing the artif...

متن کامل

Pii: S0730-725x(02)00516-7

Functional MRI (fMRI) can detect blood oxygenation level dependent (BOLD) hemodynamic responses secondary to neuronal activity. The most commonly used method for detecting fMRI signals is the gradient-echo echo-planar imaging (EPI) technique because of its sensitivity and speed. However, it is generally believed that a significant portion of these signals arises from large veins, with additiona...

متن کامل

Pii: S0730-725x(02)00508-8

A semi-automated method is described for segmenting the cerebellum from T1-weighted 3-dimensional magnetic resonance imaging scans of adult controls and patients. The method relies on prior knowledge involving a user-defined template as a guide to aid the segmentation of the cerebellum. As the gray and white matter intensity distribution in the cerebellum has a complex pattern, texture informat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002