Homogeneous time-resolved fluoroimmunoassay of thyroxin in serum.

نویسندگان

  • I Hemmilä
  • O Malminen
  • H Mikola
  • T Lövgren
چکیده

We describe a rapid, simple nonseparation fluoroimmunoassay for determination of thyroxin in serum. The assay is based on the labeling of thyroxin directly with a fluorescent europium chelate, the fluorescence of which is quenched on binding to an antithyroxin antibody. With the assay buffer we used, maximum quenching is 90%. The rapid achievement of equilibrium in the assay solution, regardless of the sequence of reagent additions, allows fast measurement of thyroxin. Precision was good (CV less than 5%) within the clinical range for total thyroxin (50-300 nmol/L), and results correlated well with those by a commercial radioimmunoassay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of a time-resolved fluoroimmunoassay for thyrotropin in routine clinical practice.

We assessed the use of a dissociation-enhanced lanthanide fluoroimmunoassay (DELFIA) system to measure thyrotropin (thyroid-stimulating hormone, TSH) in routine clinical practice. The assay is simple and precise, with intrabatch CV of less than 10% down to 0.1 milli-int. unit/L. When compared with free thyroxin, total thyroxin, and triiodothyronine measurements in 142 patients, the present assa...

متن کامل

Two new two-step immunoassays for free thyroxin evaluated: solid-phase radioimmunoassay and time-resolved fluoroimmunoassay.

We measured concentrations of free thyroxin (FT4) in serum by using two new two-step FT4 assays--a solid-phase two-step radioimmunoassay. Spectria, and a time-resolved fluoroimmunoassay. Delfia--and compared the results with those by a two-step FT4 assay (RIA-gnost), a one-step FT4 analog assay (Amerlex-M), and FT4 measured after equilibrium dialysis. The new FT4 assays classified 30 hypothyroi...

متن کامل

Determination of thyrotropin in serum by time-resolved fluoroimmunoassay evaluated.

We evaluated a new, highly sensitive time-resolved fluoroimmunoassay for thyrotropin (TSH) in serum. This direct immunometric "sandwich"-type assay involves two monoclonal antibodies against TSH, one immobilized, the other labeled with europium. Extremely high specific activity of the label and the use of labeled antibody in large excess make the method sensitive enough to measure TSH values fa...

متن کامل

Measurement of estrone-3-glucuronide in urine by rapid, homogeneous time-resolved fluoroimmunoassay.

We describe a liquid-phase nonseparation time-resolved fluorescence immunoassay for measuring estrone-3-glucuronide in undiluted urine. The sensitivity, specificity, and accuracy are similar to those for a conventional separation fluoroimmunoassay or radioimmunoassay, but the speed, convenience, precision, reliability, and clinical utility of the new method are more advantageous. The labeled an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 11  شماره 

صفحات  -

تاریخ انتشار 1988