Malfunction of the Mitral Valve Prosthesis (Cutter-Smeloff)

نویسنده

  • SIMON J. K. LEE
چکیده

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). Hemodynamic studies revealed fluctuating aortic and pulmonary artery wedge pressures in spite of normal sinus rhythm, due to impaction of the ball into the prosthetic ring, opening only with severe elevation of the left atrial pressure. At operation, the balls showed yellowish discoloration, but no disruption of sutures nor thrombosis of the prosthesis was found. The incidence of this phenomenon was 9% with the Cutter-Smeloff mitral prosthesis, but no such case was seen among patients with the Starr-Edwards mitral prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Malfunction of the mitral valve prosthesis (Cutter-Smeloff). Clinical and hemodynamic observations in three cases.

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

متن کامل

Sound spectroanalytic diagnosis of malfunctioning prosthetic heart valve.

Sound spectroanalysis was carried out for diagnosis of malfunctioning prosthetic heart valves in 50 cases, which consisted of 31 mitral, 14 aortic, 4 mitral+aortic and 1 tricuspid valve replacements with the age ranging from 17 to 57 years. Types of prosthetic valves used in this series were Starr-Edwards silicon ball valves, metal ball valves, disc valves, Kay-Shiley valves, Smeloff-Cutter val...

متن کامل

Normal function of a 43-year-old Braunwald Cutter heart valve

We present the case of a 72-year-old woman diagnosed with rheumatic fever at the age of 6. In 1972, she was diagnosed with mitral valve insufficiency and mitral valve stenosis, then in 1974, a decision was made to perform mitral valve replacement surgery with a 32-mm Braunwald-Cutter ball cage prosthesis. An echocardiogram performed in 2014 revealed normal biventricular systolic function, mecha...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Hemodynamic changes following correction of severe aortic stenosis using the Cutter-Smeloff prosthesis.

Twelve patients with pure or dominant stenosis were studied before and after aortic valve replacement (Cutter-Smeloff). The changes in cardiac output and A-V O2 difference were small and insignificant, but exercise stroke volume increased from 72 to 96 ml after the surgery. The aortic peak systolic gradient was 92 +/- 29 mm Hg before and 4 +/- 9.8 mm Hg after surgery. The PA wedge pressure, tak...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005