Two-dimensional echocardiography and Doppler color flow mapping in the diagnosis and prognosis of ventricular septal rupture.
نویسندگان
چکیده
Doppler color flow mapping in conjunction with two-dimensional echocardiography was used to evaluate ventricular septal rupture after myocardial infarction (seven anterior and eight inferior) in 15 patients and to correlate these findings with cardiac catheterization and surgical or autopsy data. Ventricular septal rupture was diagnosed by turbulent flow traversing the ventricular septum. The direction and velocity of shunt flow was determined by color M-mode and conventional Doppler methods. In all patients, Doppler color flow mapping correctly defined the site of septal rupture, which occurred at areas of discordant septal wall motion or "hinge points" (six posterior inlet, three anterior inlet, and six apical trabecular septum). Each of three patients with moderate tricuspid regurgitation and three of four patients with right-to-left shunting during diastole died, and all had an elevated right ventricular end-diastolic pressure. Right ventricular wall motion index was significantly higher in the patients who died compared with those who survived (mean +/- SEM; 2.8 +/- 0.2 vs. 2.0 +/- 0.2, p = 0.012), but there was no difference in left ventricular wall motion index. The rupture size measured by Doppler color flow imaging (1.7 +/- 0.1 cm) correlated with the size determined during surgery or autopsy (1.8 +/- 0.2 cm, r = 0.68, p = 0.022) and the pulmonic-to-systemic shunt flow ratio by cardiac catheterization (2.4:1 +/- 0.3, r = 0.74, p = 0.004). Color-guided continuous-wave Doppler estimates of right ventricular systolic pressure (47 +/- 2 mm Hg) correlated with cardiac catheterization measurements (48 +/- 3 mm Hg, r = 0.90, p = 0.0002).(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Diagnosis of ventricular septal rupture after myocardial infarction: value of colour flow mapping.
Twenty patients with ventricular septal rupture after myocardial infarction were investigated by cross sectional echocardiography with integrated pulsed and continuous wave Doppler and colour flow mapping. Confirmatory cardiac catheterisation was performed in 12 patients. Eighteen patients had surgical repair with inspection of the defect. Six patients in whom recurrent ventricular septal ruptu...
متن کاملColor Doppler detection of multiple ventricular septal defects.
Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricu...
متن کاملDIAGNOSTIC METHODS CONGENITAL HEART DISEASE Color Doppler detection of multiple ventricular septal defects
Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricu...
متن کاملDoppler echocardiographic features of ventricular septal rupture in myocardial infarction.
Doppler echocardiography was used to evaluate the features of interventricular septal rupture in six patients with acute myocardial infarction and to substantiate the hemodynamic data and morphologic findings at surgery or autopsy. Although echocardiographic visualization of the septal rupture was obtained in only two of the six patients, unusual Doppler flow signals were detected in the apical...
متن کاملSensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.
Twenty nine patients (aged from three months to 37 years) with confirmed or suspected ventricular septal defects were studied separately by three examiners who used colour flow mapping and imaging, or continuous wave Doppler and imaging, or a combined reference examination. Colour flow mapping identified 19 of the 25 patients with a ventricular septal defect, continuous wave Doppler echocardiog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 81 6 شماره
صفحات -
تاریخ انتشار 1990