Biological monitoring of benzene exposure for process operators during ordinary activity in the upstream petroleum industry.
نویسندگان
چکیده
This study characterized the exposure of crude oil process operators to benzene and related aromatics during ordinary activity and investigated whether the operators take up benzene at this level of exposure. We performed the study on a fixed, integrated oil and gas production facility on Norway's continental shelf. The study population included 12 operators and 9 referents. We measured personal exposure to benzene, toluene, ethylbenzene and xylene during three consecutive 12-h work shifts using organic vapour passive dosimeter badges. We sampled blood and urine before departure to the production facility (pre-shift), immediately after the work shift on Day 13 of the work period (post-shift) and immediately before the following work shift (pre-next shift). We also measured the exposure to hydrocarbons during short-term tasks by active sampling using Tenax tubes. The arithmetic mean exposure over the 3 days was 0.042 ppm for benzene (range <0.001-0.69 ppm), 0.05 ppm for toluene, 0.02 ppm for ethylbenzene and 0.03 ppm for xylene. Full-shift personal exposure was significantly higher when the process operators performed flotation work during the shift versus other tasks. Work in the flotation area was associated with short-term (6-15 min) arithmetic mean exposure to benzene of 1.06 ppm (range 0.09-2.33 ppm). The concentrations of benzene in blood and urine did not differ between operators and referents at any time point. When we adjusted for current smoking in regression analysis, benzene exposure was significantly associated with the post-shift concentration of benzene in blood (P = 0.01) and urine (P = 0.03), respectively. Although these operators perform tasks with relatively high short-term exposure to benzene, the full-shift mean exposure is low during ordinary activity. Some evidence indicates benzene uptake within this range of exposure.
منابع مشابه
Biological monitoring of petrochemical industry workers exposed to benzene, toluene, xylenes, methyl ethyl ketone, and phenol in Southern Iran
Background: Volatile organic compounds (VOCs), including carcinogens and toxic compounds, are produced in petrochemical industries. We undertook this study in order to study workers’ respiratory exposure to different VOC concentrations and compare the results with the urinary levels of its metabolites and study the correlation between them in petrochemical industries. Materials and Met...
متن کاملThe effect of respiratory exposure to benzene, toluene, xylene and ethyl benzene on the spirometric indices among the petroleum products loading workers
Abstract Background and Aim: Benzene, toluene, xylene and ethyl benzene (BTEX) are the most important aromatic compounds in petroleum products. BTEX compounds due to their high vapor pressure, easily change to gas form and mixed with ambient air. Petroleum products loading workers are exposed to these compounds by the inhalation of BTEX compounds. The aim of this study was to evaluate the ef...
متن کاملEvaluation of Extremely Low Frequency (ELF) Electromagnetic Fields and Their Probable Relationship with Hematological Changes among Operators in Heavy Metal Industry
Introduction: It is important that biological and health effects from the induction of currents and fields in the body by extremely low frequency (ELF) fields are fully explored to determine the effects produced at the molecular, cellular and organ levels. The objective of this study was to evaluate the intensity of ELF electromagnetic fields and its probable relationship with hematological cha...
متن کاملThe Use of Nanoaccelerator in Cement Slurries in Low Temperature Well Conditions
It has long been known that temperature during circulation and after cement placement is one of the most important parameters for slurry design and the success in cement production. Conventional cements and low density cement slurries usually take a long time to set and cannot provide significant compressive strength. Therefore, it is important to design appropriate low density cement slurries ...
متن کاملComparison of the Separation Characteristics of Polyvinyl Alcohol Membrane in Dehydration of Benzene and Toluene Using Pervaporation
Pervaporation (PV) is a well-established membrane technique used in separation; especially dehydration of organic solvents. Along with other parameters such as permeate pressure and feed temperature; feed composition is an important parameter, which affects separation characteristics and membrane performance in pervaporation. In this paper, the separation characteristics of a hydrophilic polyvi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 51 5 شماره
صفحات -
تاریخ انتشار 2007