Computed tomography in the early detection of asbestosis.

نویسندگان

  • R Bégin
  • G Ostiguy
  • R Filion
  • N Colman
  • P Bertrand
چکیده

Computed tomography (CT; both conventional (CCT) and high resolution (HRCT)) scans of the thorax were evaluated to detect early asbestosis in 61 subjects exposed to asbestos dust in Québec for an average of 22(3) years and in five controls. The study was limited to consecutive cases with chest radiographs of the International Labour Organisation categories 0 or 1 determined independently. All subjects had a standard high kilovoltage posteroanterior and lateral chest radiograph, a set of 10-15 1 cm collimation CCT scans and a set of three to five 2 mm collimation HRCT scans in the upper, middle, and lower lung fields. Five experienced readers independently read each chest radiograph and sets of CT scans. On the basis of three to five readers agreeing for small opacities of the lung parenchyma, 12/46 (26%) negative chest radiographs were positive on CT scans, but 6/18 (33%) positive chest radiographs were negative on CT scan. On the basis of four to five readers agreeing on a chest radiograph, 36/66 (54%) subjects were normal (group A), 17/66 (26%) were indeterminate (group B), and 13/66 (20%) were abnormal (group C). By the combined readings of CCT and HRCT, 4/31 (13%) asbestos exposed subjects of group A were abnormal (p < 0.001), 6/17 (35%) of group B were abnormal, and in group C, 1/13 (8%) was normal, 2/13 were indeterminate, and 10/13 (77%) were abnormal. Separate readings of CCT and HRCT on distinct films in 14 subjects showed that all cases of asbestosis were abnormal on both CCT and HRCT. Inter-reader analyses by kappa statistics showed significantly better agreement for the readings of CT than the chest radiographs (p < 0.001), and for the reading of CCT than HRCT (p < 0.01). Thus CT scans of the thorax identifies significantly more irregular opacities consistent with the diagnosis of asbestosis than the chest radiograph (20 cases on CT scans v 13 on chest radiographs when four to five readers agreed, 13% of asbestos exposed subjects with normal chest radiographs or 21% of asbestos exposed subjects with normal or near normal chest radiographs. It decreased the number of indeterminate cases significantly from 17 on chest radiographs to 13 on CT scans. All cases of asbestosis detected only on CT scans were similarly seen on CCT and HRCT and did not have significant changes in lung function. The CT scans significantly reduced the inter-reader variability, despite the absence of ILO type reference films for these scans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High resolution pulmonary computed tomography scans quantified by analysis of density distribution: application to asbestosis.

A new method for quantitative evaluation for high resolution computed tomography (HRCT) of the lungs was developed by assessment of the distribution of radiological densities within the lung slices. To enable effective reduction of data and improve the sensitivity of detection of abnormalities, the density distributions were analysed by curve fitting through the gamma variate model. The output ...

متن کامل

Early detection of interstitial lung disease in asbestos exposed non-smoking workers by mid-expiratory flow rate and high resolution computed tomography.

Ten years of lung function and radiological findings in six non-smoking asbestos exposed subjects who had increased mid-expiratory flow rate (FEF 25-75%) as the only functional abnormality were prospectively analysed. A biphasic change in FEF25-75% was noted. It initially increased up to the fifth year, and then a decrease was seen. In the final three years of the study, FEF25-75% reduction cor...

متن کامل

Early Detection of Lung Cancer Using CT Scan and Bronchoscopy in a High Risk Population

Background: Computed tomography (CT) and bronchoscopy have been shown to improve the detection rates of peripheral and central lung cancers (LC), respectively. However, the performance of the combination of CT and bronchoscopy in detecting LC, in high-risk patients, is not clear. Patients & Methods: This prospective study included 205 high-risk patients with a history of at least 2 of the follo...

متن کامل

Reliability of Persian Early Computed Tomography Score in Patients with Brain Infarction

Background: The one-third middle cerebral artery (1/3 MCA) method and Alberta Stroke Program Early Computed Tomography Score (ASPECTS) were used to detect significant early ischemic changes on brain computed tomography (CT) of patients with acute stroke. We designed the Persian Early CT Score (PECTS) and compared it with the above systems. Methods: The tomograms were chosen from the stroke data...

متن کامل

The Accuracy of Ultrasonography in Compared with Computed Tomography in Detection of Anterior Mediastinal Neoplasms

Abstract Background The aim of this study was to evaluate sensitivity and specificity of mediastinal sonography, and compared with CT, in detection of anterior mediastinal neoplasms. Materials and Methods The sonography with convex probes (5.0 and 7.5 MHz) was done prospectively for 34 patients (from 2 to 25 years old) with mediastinal mass. The results were compared with the results of ...

متن کامل

Assessment of 18F-fluorodeoxyglucose dual-head gamma camera in asbestos lung diseases.

The purpose of this study was to evaluate the performance of 18F-fluorodeoxyglucose (18FDG) imaging via coincidence detection emission tomography (CDET) in identifying malignant lesions in subjects exposed to asbestos. A total of 30 patients exposed to asbestos underwent 18FDG-CDET between January 2000 and June 2003. A CDET scan of the thorax and abdomen was performed 60 min after injection of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 1993