Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation – A first step to create reliable customized simulators
نویسندگان
چکیده
INTRODUCTION Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. METHODS Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. RESULTS All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6-3.5 times higher than in bone. For polycarbonate, forces applied were 1.6-2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. CONCLUSION Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety.
منابع مشابه
Electrical Energy Demand Modeling of 3D Printing Technology for Sustainable Manufacture
The advent of 3D printers has been embraced globally within few years of its emergence. The surge in the acceptability of rapid manufacturing RM technology can be attributed to the depletion and cost of natural resources, waste reduction and sustainability criterion of manufactured parts. This rapidly evolving 3D printing technologies is predicted to grow exponentially especially for the manufa...
متن کامل3D Rapid Prototyping for Otolaryngology—Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling
The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material parana...
متن کاملAn investigation on effect of backbone geometric anisotropy on the performance of infiltrated SOFC electrodes
Design of optimal microstructures for infiltrated solid oxide fuel cell (SOFC) electrodes is a complicated process because of the multitude of the electrochemical and physical phenomena taking place in the electrodes in different temperatures, current densities and reactant flow rates. In this study, a stochastic geometric modeling method is used to create a range of digitally realized infi...
متن کاملSafety and Efficacy of Casting During COVID-19 Pandemic: A Comparison of the Mechanical Properties of Polymers Used for 3D Printing to Conventional Materials Used for the Generation of Orthopaedic Orthoses
To reduce the risk of spread of the novel coronavirus (COVID-19), the emerging protocols are advising for less physicianpatientcontact, shortening the contact time, and keeping a safe distance. It is recommended that unnecessary castingbe avoided in the events that alternative methods can be applied such as in stable ankle fractures, and hindfoot/midfoot/forefoot injuries. Fib...
متن کاملEndoscopic Middle Ear and Mastoid Surgery for Cholesteatoma
Introduction: To reduce incidence of residual cholesteatoma following ear surgery; and to reduce the need for second look “open” mastoidectomy using endoscopic mastoidotomy. Ten-year retrospective chart review of 249 primary cholesteatoma cases (1994-2004) with a minimum follow-up of two years. The first objective was to evaluate the effectiveness of otoendoscopy in reducing the incidence of “...
متن کامل