Radiotherapy dose-distribution to the perirectal fat space (PRS) is related to gastrointestinal control-related complications

نویسندگان

  • S.L. Gulliford
  • S. Ghose
  • M.A. Ebert
  • A. Kennedy
  • J. Dowling
  • J. Mitra
  • D.J. Joseph
  • J.W. Denham
چکیده

Traditionally rectal symptoms following pelvic/prostate radiotherapy are correlated to the dosimetry of the anorectum or a substructure of this. It has been suggested that the perirectal fat space (PRS) surrounding the rectum may also be relevant. This study considers the delineation and dosimetry of the PRS related to both rectal bleeding and control-related toxicity. Initially, a case-control cohort of 100 patients from the RADAR study were chosen based on presence/absence of rectal control-related toxicity. Automated contouring was developed to delineate the PRS. 79 of the 100 auto-segmentations were considered successful. Balanced case-control cohorts were defined from these cases. Atlas of Complication Incidence (ACI) were generated to relate the DVH of the PRS with specific rectal symptoms; rectal bleeding and control-related symptoms (LENT/SOM). ACI demonstrated that control-related symptoms were related to the dose distribution to the PRS which was confirmed with Wilcoxon rank sum test (p < 0.05). To the authors knowledge this is the first study implicating the dose distribution to the PRS to the incidence of control-related symptoms of rectal toxicity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The importance of the optimal volume in the treatment of locally recurrent nasopharyngeal carcinoma; brachytherapy or stereotactic radiotherapy?

Introduction: Nasopharyngeal carcinoma (NPC) is commonly known as a radiosensitive tumor with the initial good response to radiation. Despite the improved outcome in loco regional control by the introduction of combining treatment, modern radiotherapy techniques and enhanced imaging studies, local recurrent after primary treatment with rate ranges from 15-58% in 5 years, stil...

متن کامل

معرفی روش جدید ارزیابی گاما وزن داده شده برای مقایسه توزیع دوز به دست آمده از الگوریتمهای محاسباتی دوز با نتایج تجربی در پرتودمانی

Introduction: One of the problems that exists in the quality control procedure of the treatment planning systems and the computer simulation of the radiotherapy or diagnostic radiology validation is comparing the dose distribution resulted from the dose calculation algorithms with the experimental results(as a reference). For this purpose, several methods have been proposed to compare these dos...

متن کامل

Hydrogel spacer distribution within the perirectal space in patients undergoing radiotherapy for prostate cancer: Impact of spacer symmetry on rectal dose reduction and the clinical consequences of hydrogel infiltration into the rectal wall.

PURPOSE Hydrogel prostate-rectum spacers, biomaterials placed between the prostate and rectum, continue to gain interest as a method to reduce or limit rectal dose during dose escalated prostate cancer radiation therapy. Because the spacer is initially injected into the perirectal space as a liquid, the final distribution can vary. The purpose of this study was to evaluate hydrogel spacer (Spac...

متن کامل

Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer

Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...

متن کامل

Developing a Mobile Phone Application for Common Radiotherapy Calculations

Accuracy of the radiotherapy requires some routine quality control and dosimetry calculations, which would be done by radiotherapy physicists. Due to the increasing use of computers and simulation software in medical science, as well as trends indicating its continued growth, this study aims to develop a new smart-phone application to perform common radiotherapy-related calculations. Computatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017