Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range.

نویسندگان

  • Csilla I Szabo
  • Uri Feldman
  • Stephen Seltzer
  • Lawrence T Hudson
  • Michelle O'Brien
  • Hye-Sook Park
  • John F Seely
چکیده

Two quartz (10-11) crystals were cylindrically bent to a 25.4 cm radius of curvature and were mounted in identical Cauchois-type transmission spectrometers, and the crystal diffraction efficiencies were measured to 5% absolute accuracy using narrow bandwidth x-ray source fluences in the 20 to 80 keV energy range. The measured integrated reflectivity values were compared to calculations performed using a computational model that accounts for the diffraction geometry of the bent transmission crystal. These crystal calibrations enable the accurate measurement of absolute hard x-ray emission levels from laser-produced plasmas and other laboratory sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface-treated self-standing curved crystals as high-efficiency elements for X- and γ-ray optics: theory and experiment1

The efficiency of a Laue lens for X- and γ-ray focusing in the energy range 60-600 keV is closely linked to the diffraction efficiency of the single crystals composing the lens. A powerful focusing system is crucial for applications like medical imaging and X-ray astronomy where wide beams must be focused. Mosaic crystals with a high density, such as Cu or Au, and bent crystals with curved diff...

متن کامل

Growth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics

In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...

متن کامل

Shielding simulations for safe use of curtain electron accelerator by MCNP4C

In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...

متن کامل

Evaluation of bent-crystal x-ray backlighting and microscopy techniques for the Sandia Z machine.

X-ray backlighting and microscopy systems for the 1-10-keV range based on spherically or toroidally bent crystals are discussed. These systems are ideal for use on the Sandia Z machine, a megajoule-class x-ray facility. Near-normal-incidence crystal microscopy systems have been shown to be more efficient than pinhole cameras with the same spatial resolution and magnification [Appl. Opt. 37, 178...

متن کامل

Monochromatic focusing of subpicosecond x-ray pulses in the keV range

An effective x-ray optical method to focus keV x-ray pulses shorter than one picosecond by using spherically or toroidally bent crystals is presented. The spectral, spatial, and time-dependent properties of focusing by two-dimensional bent crystals are calculated by considering geometrical effects, physical limitation in high performance crystal optics, and reflectivities obtained by x-ray diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2011