Predicting extended wear complications from overnight corneal swelling.
نویسندگان
چکیده
PURPOSE To examine the hypothesis that the corneal overnight swelling response (ONSR) is a predictor of ocular complications in contact lens extended wear (EW). METHODS The Berkeley Contact Lens Extended Wear Study (CLEWS) was a randomized, concurrently controlled clinical trial in which more than 200 subjects in EW with rigid gas-permeable (RGP) lenses were observed for 1 year. After adapting to EW, subjects were randomized to either medium or high oxygen-permeable (Dk) RGP lenses and underwent clinical assessments, keratometry, and corneal pachometry at 3-month intervals. RESULTS The ONSR was directly related to lens Dk (P = 0.01) and exhibited substantial variability across subjects. The probability of remaining free of complications over time was not significantly lower for subjects with a mild ONSR compared with those with greater edema (P = 0.84). The risk of development of keratopathy was not significantly related to the ONSR (relative risk = 1.00). CONCLUSIONS The corneal ONSR is not a good predictor of ocular complications in 1 year of RGP EW. Lenses that cause little or no corneal edema are not necessarily safer for overnight wear.
منابع مشابه
Corneal swelling response to contact lenses worn under extended wear conditions.
Corneal thickness changes were monitored in ten subjects (1) over a 36-hour period without contact lens wear and (2) during 7 days continuous wear of three types of hydrogel contact lenses of different back vertex powers. Measured on awakening, the mean overnight central corneal edema without lenses was 3.0% ± 1.2%. With the lenses used in this study, the mean overnight corneal swelling over th...
متن کاملCorneal deswelling response to hard and hydrogel extended wear lenses.
The amount of initial corneal swelling and the time course of corneal deswelling were measured after overnight wear of several types of hard and hydrogel lenses. Deswelling occurred in the right eye with the lens still on the cornea. In the left eye the lens was removed at eye opening and left off the cornea during deswelling. For lenses of equal nominal oxygen transmissibility, hard lenses ini...
متن کاملImpact of rigid gas-permeable contact lens extended wear on corneal epithelial barrier function.
PURPOSE To measure the effect of hypoxia and eye closure on epithelial permeability to fluorescein (P(dc)) during rigid lens extended wear (EW). METHODS Central corneal thickness (CT) and P(dc) were measured in 42 subjects with an optical pachometer and automated scanning fluorophotometer, respectively. All subjects had been successfully wearing rigid gas-permeable (RGP) lenses on a 6-night E...
متن کاملCritical oxygen levels to avoid corneal edema for daily and extended wear contact lenses.
The relationship between corneal edema and hydrogel lens oxygen transmissibility was examined for both daily and extended contact lens wear by measuring the corneal swelling response induced by a variety of contact lenses over a 36-hr wearing period. The relationships derived enable average edema levels that occur with daily and extended wear in a population of normal young adults to be predict...
متن کاملCorneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor.
PURPOSE To assess the effect of overnight wear of a contact lens-based sensor (CLS) for monitoring of 24-hr intraocular pressure (IOP) fluctuations on central corneal thickness (CCT). MATERIALS AND METHODS Changes in the CCT, mid-peripheral corneal thickness and central corneal radius (CCR) during overnight CLS wear in 20 eligible patients with ocular hypertension or established glaucoma wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 42 13 شماره
صفحات -
تاریخ انتشار 2001