A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.

نویسندگان

  • V DeCaprio
  • P Hurzeler
  • S Furman
چکیده

Simultaneous unipolar and bipolar electrograms were recorded and compared from 49 pacemaker patients with bipolar endocardial electrodes. Average bipolar depolarization signal voltage equalled that of unipolar but showed greater variation. Bipolar and unipolar slew rates were equal in both mean and variance. The proximal pole voltage had little effect on the bipolar result in 8% of the cases, tended to cancel the tip voltage in 49% of the cases and augmented the tip voltage in 43% of the electrograms. The average bipolar R wave duration was 28% less, the T wave amplitude 34% less, and the ST-segment elevation 37% less than the unipolar values. By consistently attenuating the undersirable T waves and ST elevations, while leaving the depolarization signal unaffected, the bipolar electrode offered the advantage of a superior signal-to-noise ratio for sensing depolarization. In one case, however, the bipolar signal was so small as to cause a clinical sensing failure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter to the Editor: Marino et al. Inappropriate mode switching clarified by using a chest radiograph

To the Editor, I read with great interest the article by Marino et al. entitled “Inappropriate mode switching clarified by using a chest radiograph.” [1]. The authors have explained a case of dual-chamber pacemaker malfunction, caused by intermittent high-frequency noises. They claimed that this happened because of lead–lead interaction caused by excess slack of atrial and ventricular leads. In...

متن کامل

Conducting randomized trials in the electrophysiology laboratory: lessons from a randomized comparison of recording methods during pulmonary vein isolation by segmental ostial ablation.

Accurate identification of pulmonary vein (PV) potentials during segmental ostial ablation for PV isolation is very important to completely isolate the PVs and also to avoid unnecessary applications of radiofrequency energy. A prior post hoc analysis of unipolar and bipolar electrograms recorded from successful and unsuccessful ablation sites demonstrated that unipolar electrograms recorded at ...

متن کامل

Pulmonary vein isolation: comparison of bipolar and unipolar electrograms at successful and unsuccessful ostial ablation sites.

INTRODUCTION No prior studies have quantitatively analyzed the characteristics of bipolar or unipolar electrograms that may be helpful in identifying successful ostial ablation sites in patients with atrial fibrillation undergoing segmental pulmonary vein isolation. METHODS AND RESULTS The characteristics of bipolar and unipolar electrograms recorded at 185 successful and 120 unsuccessful ost...

متن کامل

From Unipolar to Bipolar Leads: Fewer Problems, More Advantages?

The cardiac pacemaker lead, the "Achilles heel" of pacing hardware, is a relatively fragile cable of insulated conductor wire implanted into the hostile environment of the human body [1]. The ideal pacing lead remains an elusive goal. Important lead characteristics include ease of surgical insertion with safe and reliable fixation in the myocardium and a high level of electrical performance [2]...

متن کامل

Methods for recording electrograms of the sinoatrial node during cardiac surgery in man.

Recent reports have shown that it is possible to record extracellular electrograms from the rabbit and dog sinoatrial (SA) node. We applied similar techniques to record SA nodal activity in 23 patients who underwent cardiac surgery for various forms of heart disease. Both a bipolar technique, using pairs of electrodes at various interelectrode distances, and a unipolar technique, using an explo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 1977