A flat flame burner for the calibration of laser thermometry techniques

نویسنده

  • G Hartung
چکیده

The design and experimental characterization of a burner is described, which has favourable characteristics for the accurate calibration of a range of optical thermometry techniques. The burner supports stable laminar flames and combines many of the advantages of several widely used burner designs without their disadvantages. It permits the application of point measurement techniques, line-of-sight techniques and planar imaging techniques; trace species, such as metal atoms, can be easily introduced into the flame. The implementation of the burner is described, followed by the presentation of data obtained from coherent anti-Stokes Raman scattering (CARS) measurements and numerical simulations. Spatially resolved measurements were performed over the entire flame profile at three different stoichiometries and factors causing systematic and random errors are described in detail. Measurement errors on mean temperatures were determined to be less than 1%. The shot-to-shot measurement precision was determined to be 3.5–4.0% (FWHM of temperature probability density function). The burner design together with the data presented in this paper can be used for the validation and calibration, respectively, of a variety of combustion thermometry techniques. Complete details of the burner design together with the obtained temperature data will be provided on the World Wide Web. Other researchers intending to validate and calibrate their own laser-based thermometry techniques will be able to cost-effectively reconstruct this burner and adopt the characterization presented here, thus being able to apply it without the need of their own basic validation. The authors are confident that a reconstructed burner, which is applied under the same conditions, will yield the same high level of accuracy and precision as that presented in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A method for performing high accuracy temperature measurements in low-pressure sooting flames using two-line atomic fluorescence

We demonstrate a step change in the capability of diode laser excited two-line atomic fluorescence (TLAF) thermometry and show it is well-suited to the study of low-pressure sooting flames. The new developments to the technique reported here were essential to achieve the accuracy (±41 K) and precision (±8 K) required for useful measurements in such systems. This represents the first application...

متن کامل

Tomographic analysis of CO absorption in a low-pressure flame.

Tomographic analysis is used to provide a correction to low-pressure stoichiometric premixed CH(4)/O(2) flame temperatures measured with tunable diode laser absorption spectroscopy employing CO two-line thermometry. It is shown that flame temperatures measured with line-of-sight-based two-line thermometry are always too low and that the correction to the observed temperature is a nonlinear func...

متن کامل

Soot diagnostics at elevated pressure: Laser-induced incandescence and multi-line NO-LIF thermometry

This article presents tools for soot diagnostics at elevated pressure. Investigations on laser-induced incandescence (LII) are shown in a laminar premixed ethylene/air flame at pressures up to 5 bar in a recently constructed high-pressure burner. The LII signal decay was compared to results of a numerical model taking into account the pressure-dependent heat transfer. Required input parameters ...

متن کامل

Diode laser atomic fluorescence temperature measurements in low-pressure flames

Temperature measurements have been performed in a low-pressure flame by the technique of diode laser induced atomic fluorescence. The experiments were done in a near-stoichiometric flat-flame of premixed methane, oxygen and nitrogen, at a pressure of 5.3 kPa. Indium atoms were seeded to the flame and probed using blue diode lasers; the lineshapes of the resulting fluorescence spectra were used ...

متن کامل

Laser-induced incandescence and multi-line NO LIF thermometry for soot diagnostics at high pressures

Laser-induced incandescence (LII) is investigated in laminar premixed flat ethylene/air flames at pressures up to 5 bar in a recently constructed high-pressure burner. Time-resolved LII signals were compared with a numerical model considering the influence of pressure on the LII signal decay. Peak particle temperatures after laser heat up were measured by the detection of the LII signal at two ...