Evaluation of a New 240-lm Single-Use Holmium:YAG Optical Fiber for Flexible Ureteroscopy

نویسنده

  • Tariq A. Khemees
چکیده

Background and Purpose: Numerous holmium:yttrium-aluminum-garnet laser fibers are available for flexible ureteroscopy. Performance and durability of fibers can vary widely among different manufacturers and their product lines with differences within a single product line have been reported. We sought to evaluate a newly developed nontapered, single-use 240-lm fiber, Flexiva 200 (Boston Scientific, Natick, MA), during clinical use and in a bench-testing model. Materials and Methods: A total of 100 new fibers were tested after their use in 100 consecutive flexible ureteroscopic lithotripsy procedures by a single surgeon (B.K.). Prospectively recorded clinical parameters were laser pulse energy and frequency settings, total energy delivered and fibers failure. Subsequently, each fiber was bench-tested using an established protocol. Parameters evaluated for were fibers true diameter, flexibility, tip degradation, energy transmission in straight and 180 bend configuration and fibers failure threshold with stress testing. Results: The mean total energy delivered was 2.20 kJ (range 0–18.24 kJ) and most common laser settings used were 0.8 J at 8 Hz, 0.2 J at 50 Hz, and 1.0 J at 10 Hz, respectively. No fiber fractured during clinical procedures. The true fiber diameter was 450 lm. Fiber tips burnt back an average of 1.664 mm, but were highly variable. With laser setting of 400 mJ at 5 Hz, the mean energy transmitted was 451 and 441 mJ in straight and 180 bend configuration, respectively. Thirteen percent of fibers fractured at the bend radius of 0.5 cm with a positive correlation to the total energy transmitted during clinical use identified. Conclusion: Fiber performance was consistent in terms of energy transmission and resistance to fracture when activated in bent configuration. Fiber failure during stress testing showed significant correlation with the total energy delivered during the clinical procedure. The lack of fiber fracture during clinical use may reduce the risk of flexible endoscope damage due to fiber failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new 240-μm single-use holmium:YAG optical fiber for flexible ureteroscopy.

BACKGROUND AND PURPOSE Numerous holmium:yttrium-aluminum-garnet laser fibers are available for flexible ureteroscopy. Performance and durability of fibers can vary widely among different manufacturers and their product lines with differences within a single product line have been reported. We sought to evaluate a newly developed nontapered, single-use 240-μm fiber, Flexiva™ 200 (Boston Scientif...

متن کامل

Evaluation of Holmium:YAG Laser Optical Fibers for Flexible Ureteroscopy using a Relevant Benchtop Model

Materials and Methods. Testing was conducted on single-use and reusable laser fibers in varying sizes – 200μm, 272μm, 365μm, 550μm and 1000μm. Sizes reflect the true core diameter of each fiber. Fixtures for the testing were built for the 200μm, 272μm, 365μm, 550μm fibers simulating the anatomical curvature that the fiber may be subjected to during a procedure (considered the short-term bend ra...

متن کامل

URETEROSCOPY IN 104 PATIENTS

From July, 1987 to Oct, 1989 , 104 patients underwent 111 transurethral ureteroscopy procedures at the Air Force Medical Center. All intramural ureters were dilated by flexible metal dilators. The overall success rate for ureteral stone removal was 95.8 per cent. Ureteroscopy was done for evaluation of gross hematuria, strictures, ureteral stent, and ureteral and pyelocalyceal tumors. The ...

متن کامل

Antegrade Flexible Ureteroscopy for Bilateral Ureteral Stones in a Patient with Severe Hip Joint Ankylosis

In the past several decades there has been a remarkable development of small-caliber, flexible ureteroscopes and various ancillary instruments for stone manipulation and retrieval. Percutaneous antegrade ureteroscopy can be substituted in select cases for retrograde ureteroscopy. We report a case of a 60-year-old man with severe ankylosis in both hip joints who was diagnosed with bilateral uret...

متن کامل

Is the holmium:YAG laser the best intracorporeal lithotripter for the ureter? A 3-year retrospective study.

PURPOSE To study the efficiency and safety of holmium:YAG laser lithotripsy for ureteral stones. PATIENTS AND METHODS A series of 188 patients with 208 ureteral stones were treated with semirigid ureteroscopy and holmium:YAG laser lithotripsy from January 2003 to December 2005. Of the stones, 116 were lower ureteral, 37 middle ureteral, and 55 upper ureteral. RESULTS The success rate was 92...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013