Biomechanics of the lumbar spine after dynamic stabilization.
نویسندگان
چکیده
Target of the study was to predict the biomechanics of the instrumented and adjacent levels due to the insertion of the DIAM spinal stabilization system (Medtronic Ltd). For this purpose, a 3-dimensional finite element model of the intact L3/S1 segment was developed and subjected to different loading conditions (flexion, extension, lateral bending, axial rotation). The model was then instrumented at the L4/L5 level and the same loading conditions were reapplied. Within the assumptions of our model, the simulation results suggested that the implant caused a reduction in range of motion of the instrumented level by 17% in flexion and by 43% in extension, whereas at the adjacent levels, no significant changes were predicted. Numerical results in terms of intradiscal pressure, relative to the intact condition, predicted that the intervertebral disc at the instrumented level was unloaded by 27% in flexion, by 51% in extension, and by 6% in axial rotation, while no variations in pressure were caused by the device in lateral bending. At the adjacent levels, a change of relative intradiscal pressure was predicted in extension, both at the L3/L4 level, which resulted unloaded by 26% and at the L5/S1 level, unloaded by 8%. Furthermore, a reduction in terms of principal compressive stress in the annulus fibrosus of the L4/L5 instrumented level was predicted, as compared with the intact condition. These numerical predictions have to be regarded as a theoretical representation of the behavior of the spine, because any finite element model represents only a simplification of the real structure.
منابع مشابه
Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review
STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "...
متن کاملبررسی تأثیر تمرینهای فعال ثبات دهنده ستون فقرات بر عملکرد عضلات کمر در صفحه ساجیتال در افراد سالم
Musculoskeletal disorders which are introduced with back pain are now the most common cause of chronic incapacity in industrialized countries. One of the important causes of low back pain is, spinal instability. A recent focus in the physiotherapy management of patients with back pain has been the active spinal stabilization exercises of muscles surrounding the spine considered to provi...
متن کاملDevelopment and testing of a moment-based coactivation index to assess complex dynamic tasks for the lumbar spine.
BACKGROUND Many methods exist to describe coactivation between muscles. However, most methods have limited capability in the assessment of coactivation during complex dynamic tasks for multi-muscle systems such as the lumbar spine. The ability to assess coactivation is important for the understanding of neuromuscular inefficiency. In the context of this manuscript, inefficiency is defined as th...
متن کاملBiomechanics of a Posterior Lumbar Motion Stabilizing Device: In Vitro Comparison to Intact and Fused Conditions.
STUDY DESIGN Nondestructive flexibility tests were performed in vitro, comparing multiple conditions of fixation in a single group of specimens. OBJECTIVE To compare the biomechanical behavior of the lumbar spine in the intact condition, after implanting a novel motion stabilizer, and after implanting a rigid fixator. SUMMARY OF BACKGROUND DATA Two specific scenarios that may benefit from d...
متن کاملStress Analysis of the Human Ligamentous Lumber Spine-From Computer-Assisted Tomography to Finite Element Analysis
Detailed investigation on biomechanics of a complex structure such as the human lumbar spine requires the use of advanced computer-based technique for both the geometrical reconstruction and the stress analysis. In the present study, the computer-assisted tomography (CAT) and finite element method (FEM) are merged to perform detailed three dimensional nonlinear analysis of the human ligamentous...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of spinal disorders & techniques
دوره 20 6 شماره
صفحات -
تاریخ انتشار 2007